82
Get-Function table
A.
Basic function
Get Function Length ID Command
Type
Command
Response Range
Comments
(ASCII)
Code (ASCII) Code (Hex) (Three ASCII bytes)
Get-Bright-
ness
8
g
b
62
000 ~ 100
Get-Volume
8
g
f
66
000 ~ 100
Get-Mute
8
g
g
67
000: Off
001: On (muted)
Get-Input
select
8
g
j
6A
000~
100~
1. 1st digit for signal
detection: 0
means “no signal”;
1 means “signal
detected”
2. 2nd &3rd digit:
See Set-function
table
Get-Power
status: ON/
STBY
8
g
l
6C
001: ON
000: STBY
Get-Remote
control
S
g
n
6E
000: Disable
001: Enable
002: Pass through
Get RCU mode
status
Get-Power
lock
8
g
o
6F
000: Unlock
001: Lock
Get-Button
lock
8
g
p
70
000: Unlock
001: Lock
Get-Menu
lock
8
g
l
6C
000: Unlock
001: Lock
Get-ACK
8
g
z
7A
000
This command is
used to test the com-
munication link
Get-Thermal
8
g
0
30
000~100:
0~+100 deg C
-01~-99:
-1~-99 deg C
Get-Opera-
tion time
*3.1.0
8
g
1
31
000
1. Accumulated
hours in 8-digit in-
teger (00,000,001~
99,999,999)
2. Could be reset
when FW update
and Factory initia-
tion
3. Reply in 4 strings
Get-Device
name
8
g
4
34
000
Reply in 6 strings
(max. 12 characters)
*3.1.0
Get-MAC ad-
dress
8
g
5
35
000
(for the model with
LAN)
Reply in 6
strings.
*3.1.0