75
Set-Function format
Send: (Command Type=”s”)
Name Length
ID
Command
Type
Command Value1 Value2 Value3 CR
Byte
Count
1 Byte 2 Byte
1 Byte
1 Byte
1 Byte 1 Byte 1 Byte 1 Byte
Bytes
order
1
2~3
4
5
6
7
8
9
Reply: (Command Type=”+” or “-”)
Name
Length
ID
Command
Type
CR
Byte
Count
1 Byte 2 Byte
1 Byte
1 Byte
Bytes
order
1
2~3
4
5
NOTE:
1.
When PC applies command to all displays (ID=99), only the #1 set needs to reply
by the name of ID=1.
Example1: Set Brightness as 76 for Display (#02) and this command is valid
Send (Hex Format)
Name Length
ID
Command
Type
Command Value1 Value2 Value3 CR
Hex
0x38
0x30
0x32
0x73
0x24
0x30
0x37
0x36 0x0D
Reply (Hex Format)
Name
Length
ID
Command
Type
CR
Hex
0x34
0x30
0x32
0x2B
0x0D
Example2: Set Brightness as 75 for Display (#02) and this command is NOT
valid
Name Length
ID
Command
Type
Command Value1 Value2 Value3 CR
Hex
0x38
0x30
0x32
0x73
0x24
0x30
0x37
0x35 0x0D