Get-Function format
Send: (Command Type=”g”)
Name Length
ID
Command
Type
Command Value1 Value2 Value3 CR
Byte
Count
1 Byte 2 Byte
1 Byte
1 Byte
1 Byte 1 Byte 1 Byte 1 Byte
Bytes
order
1
2~3
4
5
6
7
8
9
NOTE:
Get “Power STBY status” is the exception for VT2405LED-1 and
VT3205LED.
Reply: (Command Type=”r” or “-”)
If the Command is valid, Command Type =”r”
Name Length
ID
Command
Type
Command Value1 Value2 Value3 CR
Byte
Count
1 Byte 2 Byte
1 Byte
1 Byte
1 Byte 1 Byte 1 Byte 1 Byte
Bytes
order
1
2~3
4
5
6
7
8
9
NOTE:
The reply for “Power STBY status” command is the exception for
VT2405LED-1 and V3205LED. It’s 0x36 72 6C 30 30 30 0D ( 6rl000<CR>).
If the Command is Not valid, Command Type=”-“
Name Length
ID
Command
Type
CR
Byte
Count
1 Byte 2 Byte
1 Byte
1 Byte
Bytes
order
1
2~3
4
5
Example1: Get Brightness from TV-05 and this command is valid.
The Brightness value is 67.
Send (Hex Format)
Name Length
ID
Command
Type
Command Value1 Value2 Value3 CR
Hex
0x38
0x30
0x35
0x67
0x62
0x30
0x30
0x30 0x0D
Reply (Hex Format)
Name Length
ID
Command
Type
Command Value1 Value2 Value3 CR
Hex
0x38
0x30
0x35
0x72
0x62
0x30
0x36
0x37 0x0D