Get function table:
Get Function
Length
ID
Command
Type
Command Value
Range
Comments
Code (ASCII)
Code (Hex)
(Three ASCII bytes)
Get-Contrast
8
g
a
61
000 ~ 100
Gets Contrast value
Get-Brightness
8
g
b
62
000 ~ 100
Gets Brightness value
Get-Sharpness
8
g
c
63
000 ~ 100
Gets Sharpness value
Get-Color
8
g
d
64
000 ~ 100
Gets Color value
Get-Tint
8
g
e
65
000 ~ 100
Gets Tint value
Get-Volume
8
g
f
66
000 ~ 100
Gets Volume value
Get-Mute
8
g
g
67
000: OFF (unmuted)
001: ON (muted)
Gets Mute ON/OFF
status
Get-Input select
8
g
j
6A
000~
See Set-function table
Get-Power
status : ON/
STBY
8
g
l
6C
000: STBY
001: ON
Get-Remote
control
8
g
n
6E
000 : Disable
001 : Enable
002 : Pass through
Get-Power Lock
8
g
o
6F
000 : Unlock
001 : Lock
Get-Button Lock
8
g
p
70
000 : Unlock
001 : Lock
Get-Menu Lock
8
g
q
71
000 : Unlock
001 : Lock
Get-PIP Mode
8
g
t
74
000 : OFF
001 : PIP
002 : PBP
Get-PIP Input
8
g
u
75
000~
See Set-function table
Get-Tiling Mode
8
g
v
76
000 : OFF
001 : ON
Get-Tiling
Compensation
8
g
w
77
000 : OFF
001 : ON
Get-Tiling H by V
monitors
8
g
x
78
01x~09x: H monitors
0x1~0x9 : V monitors
1. 2nd digital for H
monitors
2. 3rd digital for V
monitors
Get-Tiling
Position
8
g
y
79
000 : OFF
001~025
Get-ACK
8
g
z
7A
000
This command is
used to test the
communication link.