background image

VIEWEG

EN

Operating Manual DC 200

Contents

1   General information .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .   13

1.1  The DC 200  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .   13
1.2  Intended Use.  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .   13
1.3  Scope of delivery  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .   14

2   Safety instructions  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .   15

2.1  General safety information  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .   15
2.2  Dangers for the operator  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .   15
2.3  Electrical safety instructions   .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .   15
2.4  Safety Instructions for Auxiliary and Operating Materials  .  .  .  .  .  .  .  .  .  .  .  .   15

3   About your dispensing unit  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .   16
4   Start & Operation.  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .   17
5   Time Ranges.  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .   18
6   Connections.  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .   19
7   Disposal  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .   19
8   Technical data.  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .   20
9   Technical connections  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .   20

9.1  Foot switch  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .   20

10 Declaration of Conformity  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .   21

12

13

Summary of Contents for DC 200

Page 1: ...DE Bedienungsanleitung Dosierger t DC 200 EN Operating Manual Dispenser DC 200 VIEWEG...

Page 2: ...eral safety information 15 2 2 Dangers for the operator 15 2 3 Electrical safety instructions 15 2 4 Safety Instructions for Auxiliary and Operating Materials 15 3 About your dispensing unit 16 4 Star...

Page 3: ...ontaining 3 to 55 cc By means of a compressed air regulator the dispensing pressure can be applied to the The dispensing material can be adjusted exactly A digital pressure monitor controls the inlet...

Page 4: ...00 Dispensing unit cold appliance cable 230 V AC Item no C 0043 connection hose for compressed air inlet Item no C 0042 barrel holder Item no C 0041 foot switch Item no C 0040 barrel adapter 30 cc Ite...

Page 5: ...ble media This device is intended for indoor use only 2 3 Electrical safety instructions Risk of death due to electric shock There is a danger to life inside the dispensing unit due to mains voltage B...

Page 6: ...ng vacuum suck back 2 Pressure gauge for compressed air outlet 3 Pressure regulator 4 Adjustable dispense time 5 Status LED 6 Timer ON OFF 7 Compressed air output 11 Connection for foot switch 12 Main...

Page 7: ...apter like following diagram Connect the air tube of the cartridge adapter to the air pressure output of the DC 200 and adjust the pressure fur the cartridge on the front side with the pressure contro...

Page 8: ...ON 0 21 21 0 sec OFF ON ON 0 11 11 0 sec ON ON ON 0 31 31 0 sec DIP switch 4 switches an extra mode in which the signal is held at ON and a manual mode is selected at OFF 5 Time Ranges With the poten...

Page 9: ...with the applicable regulations Electrical parts must not be disposed of with household waste According to Directive 2012 19 EU on Waste Electrical and Electronic Equipment WEEE these must be returned...

Page 10: ...erial or dispensing pressure DC 215 0 1 bar DC 270 0 7 bar Available models DC 215 0 1 bar DC 270 0 7 bar 9 Technical connections 9 1 Foot switch Assignment Closing contact between pin 1 3 starts the...

Page 11: ...tion as well as the version marketed by us complies with the applicable regulations the relevant provisions Product Dispenser Type DC 200 Series Manufacturer VIEWEG Dosier und Mischtechnik Gewerbepark...

Page 12: ...www dosieren de VIEWEG GmbH Dosier und Mischtechnik Gewerbepark 13 85402 Kranzberg Deutschland Germany Tel 49 8166 6784 0 info dosieren de www dosieren de www dosieren de VIEWEG...

Reviews: