8 Technical data
Outer dimensions (W x H x D)
235 x 225 x 75 mm
weight
approx. 1.25 kg
Power supply
85 - 264 V AC 50/60 Hz
Internal voltage
24 V DC
Dispensing duration
0.01 - 31 sec.
Compressed air input
0 – 7 bar
Compressed air Output
Material or dispensing pressure
DC 215:
0 - 1 bar
DC 270:
0 - 7 bar
Available models
DC 215:
0 - 1 bar
DC 270:
0 - 7 bar
9 Technical connections
9.1 Foot switch
Assignment:
Closing contact between pin 1 + 3 starts the dispensing process
DC 200
4k7
33R
GND
WS
SW
The footswitch input signal is activated
when the input pin is short-circuited to
the GND pin.
Do not insert an external
supply voltage on! This can lead to a
defect in the device.
Foot
switch
Input
Microcontroller
1
3
20
21