21
ENGLISH
Turn-table
20
General Specification
Trouble Shooting
Sometimes, an operational fault can be mistaken for a malfunction or failure. Check the following points and
see if you can find the symptoms of the trouble below before you get in touch with the serviceman. If you
cannot locate the symptoms, contact your nearest dealer.
Symptom
Possible Trouble
Remedy
Platter does not
rotate.
Power cord is unplugged.
Plug cord securely into wall outlet.
Phono cables are not connected
properly.
Connect cables securely to the PHONO input
jacks on the amplifier (see page 19).
Headshell is not properly attached.
Fimly secure tonearm locking collar.
No Sound.
Platter speed is not set properly.
Refer to “Controls and operation” and their
uses on page 18.
Musical
tempois
off.
1. APPLICATION
This spectftcation applies to the belt drive turntable unit VH-TT500SL
2. STANDARD TEST CONDITION :
2-1 Ambient Temperrature
23 A 2LC
2-2 Relative Humidity
65% A 5%
NOTE : Measurements can be carried out betwee 5LC and 45% to 85% relative humidity.
3. TURNTABLE SECTION:
3-1
Type
2-speed full manual
3-2
Motor
DC
motor
3-3
Driving
Method belt drive
3-4
Turntable plater
330mm dia. Aluminium
3-5
Speeds
33-1/3 and 45 rpm
3-6
Wow and Flutter
Less than 0.25% WRMS(JIS WTD)
3-7
S/N ratio
More than 50 dB(DIN-B)
3-8
Pitch Controls
+/- 10%
3-9
Starting Time
Less than 1 sec.
3-10
Time for speed change
Less than 1 sec.
3-11
Speed to lerance at pitch=0
/- 1.3%
3-12
High of cue (first track)
Normal 7~9.5mm, Limit 6~10.5mm
4. TONEARM SECTION
4-1
Type
Static balanced S-shaped tone arm with
detachable
headshell
4-2
Effective Arm Length
220mm
4-3
Overhang
10mm
4-4
Tracking error
Less than 3 degree
4-5
Tracking Force Adiustment range
0-4g
4-6
Applicable cartidge weight
6-10g
4-7
Anti-skating range
0-4g
4-8
Tracking force range of attached cartridge
3.5 +/-0.5g
5. GENERAL SECTION:
5-1
Power Supply
AC 230V ~ 50Hz
5-2
Power consumption
8 Watts
5-3
Dimensions
450(W) X 350(D) X 139(H) mm
5-4
Weight
4.38Kgs
6. ACCESSORIES SUPPLIED
7. SPECIFICATION:
DESCRIPTIONS
UNIT
NOMINAL
LIMIT
(1) Output Difference
dB
2.3
2.5
(2) Output Level
mv
1.7~3.5
1.5~3.5
(3) Speed (Speed range)
Hz
2.7K
i
, 3.3K
h
2.7K
i
, 3.27K
h
(4) Speed (Center Range)
Hz
2970~3030
2965~3030
(5) Wow and Flutter
%
0.23
0.25
(6) Channel separtion
dB
16
15
Cartridge lead wires are loose.
Attach lead wires inside headshell properly.
Amplifier is not being operated
properly.(function switch, tape
monitor switch, speak switches, etc.
are not set correctly).
Read the operating instructions that come
with amplifier.
SPEED ADJUSTMENT knob is not set
properly in accordance with the platter
speed.
Connect properly to the amplifier’s ground
terminal (see page 19).
Ground lead is not connected.
Refer to tracking force adjustment on page 17.
Excessive
noise.
Tracking for is not correct.
Clean the stylus tip with a soft brush.
Dust or dirt has collected on the
stylus tip.
Dust or dirt has collected on the
record.
Dust or dirt has collected on the
stylus tip.
Tracking force is not correct.
Sound is
distorted.
Stylus is worn.
Amplifier’s tone controls are set
too high.
Cueing Laver is set to UP
position.
Trading force is not correct.
Tonearm does not
descend.
Tracking force is not correct.
Intermittent
sound.
Stylus is worn.
Record is scratched or warped.
Refer to “Operating Procedure” on page 18.
Clean the record with a good quality cleaner.
Clean the stylus tip with a soft brush.
Refer to tracking force adjustment on page 17.
Replace with new stylus.
Set tone controls to lower position.
Set to DOWN position.
Refer to tracking force adjustment on page 17.
Refer to tracking force adjustment on page 17.
Replace with new stylus.
Replace record.