VIET GARDEN FX Troubleshooting Manual Download Page 5

 

A Hunter Industries Company 

 

5.  LX - Hard Reset 

 Electrical surges and voltage spikes can cause anomalies in a transformers face pack. 

  

 

 

 

 

 

 

 

6.  LX - Moving the Photocell 

FX manufactures an extended version of the LX Photocell with a lead to mount photocell up to 

26' from transformer 

 

  

 

 

 

 

 

 

To return the face pack to its original setting 

complete the reset procedure listed below: 

1.  Hold  down  the  GREY  ENTER and 

DOWN button on the face pack. 

2.  As you are holding the buttons down, 

press the reset button on the back of 

the face pack. 

3.  Release  the  reset  button  first,  and 

then release the buttons on the front. 

A successful reset will result in 12:00 on the 

display.  You  can  now  reprogram  your  LX 

face pack. 

 

Kit Includes: 

 

26' of cable 

 

Mounting bracket 

 

Mounting Screws 

The FX part number for the LX extended 

photocell is LX-PC-KIT  

 

 

Summary of Contents for FX

Page 1: ...lem Lamps are burning out prematurely Cause Excessive voltage at lamp Solution Drop the affected cable run down to the next lower voltage tap or increase wattage load on that cable to drop voltage Also some lamps are rated for a very short life such as the 4414 300 hours Use halogen lamps Problem The closest lamp to the transformer is burning out prematurely Cause Excessive voltage at lamp Solutio...

Page 2: ... make a good connection to the lamp base Problem System is getting dimmer with age Cause Splices are corroding Solution As non waterproof splices corrode they create electrical resistance which reduces voltage Problem Photocell transformer is coming on too soon Cause Transformer is in dark location Solution In order to operate properly the photocell must have a good look at daylight Move to a brig...

Page 3: ...s you the opportunity to utilize the voltage tap that will provide each circuit with the proper voltage For cable runs in the distant zone you would typically select the 13 or 14 volt tap For cable runs in the close zone you would typically install the cable run into the 12 volt tap depending upon the wattage load and size of cable This tool tells you whether or not the 120 volt receptacle you are...

Page 4: ...he Electrical Panel to the receptacle is OK or not If it does not indicate two orange lights something is wrong with the wiring Consult an electrician 4 LX Testing Transformer Power The first test to perform will determine if power is passing through the Transformer to the low voltage taps Turn your volt meter on and place one of the probes on the lug labeled C and the other probe on the voltage t...

Page 5: ... original setting complete the reset procedure listed below 1 Hold down the GREY ENTER and DOWN button on the face pack 2 As you are holding the buttons down press the reset button on the back of the face pack 3 Release the reset button first and then release the buttons on the front A successful reset will result in 12 00 on the display You can now reprogram your LX face pack Kit Includes 26 of c...

Page 6: ... the top of the transformer This fuse does not protect the incoming voltage just the low voltage side of the transformer The LX buss fuse is located in the top wiring compartment of the LX lighting transformer Replace with a UL Listed 3AG with the following specifications 10 Amp 250V This procedure should only be performed by a licensed electrician Disconnect power from the primary and secondary U...

Page 7: ...e transformer is tested in the field 9 LX Replacement Lamp Not Working A common mistake made by many is to replace existing lamps with lamps of higher wattage than those originally installed Example If you have an FX system with a PX 600 watt transformer 25 fixtures illuminating the landscape and all of the original fixtures have 20 watt lamps in them for a total load on the transformer of 500 wat...

Reviews: