VIET GARDEN FX Troubleshooting Manual Download Page 2

 

A Hunter Industries Company 

 

 

Problem 

Lamps have a 
yellow or golden 
tone 

 

Cause 

 

Voltage too low 

Solution 

 

Move affected cable to the next higher voltage tap or reduce 

load on cable. If possible, run additional cable to first fixture 

to reduce voltage loss. 

 

Problem 

Lamp goes on and 
off when fixture is 
moved 

 

Cause 

 

Too much tension on socket leads 

Solution 

 

With spring type sockets, it is important to leave some slack 

so the socket contacts make a good connection to the lamp 

base. 

 

 

Problem 

System is getting 
dimmer with age 

 

Cause 

 

Splices are corroding 

Solution 

 

As non-waterproof splices corrode, they create electrical 

resistance, which reduces voltage. 

 

Problem 

Photocell 
transformer is 
coming on too soon 

Cause 

 

Transformer is in dark location 

Solution 

 

In order to operate properly, the photocell must have a good 

look at daylight. Move to a brighter location. 

 

Problem 

Fixtures have a 
white mineral 
deposit on them 

Cause 

 

Irrigation water is hitting them 

Solution 

 

Schedule the irrigation to come on after the lights have gone 

off. This is especially true with the 50 W spots 

— very hot. 

 

 

 
 

 

Summary of Contents for FX

Page 1: ...lem Lamps are burning out prematurely Cause Excessive voltage at lamp Solution Drop the affected cable run down to the next lower voltage tap or increase wattage load on that cable to drop voltage Also some lamps are rated for a very short life such as the 4414 300 hours Use halogen lamps Problem The closest lamp to the transformer is burning out prematurely Cause Excessive voltage at lamp Solutio...

Page 2: ... make a good connection to the lamp base Problem System is getting dimmer with age Cause Splices are corroding Solution As non waterproof splices corrode they create electrical resistance which reduces voltage Problem Photocell transformer is coming on too soon Cause Transformer is in dark location Solution In order to operate properly the photocell must have a good look at daylight Move to a brig...

Page 3: ...s you the opportunity to utilize the voltage tap that will provide each circuit with the proper voltage For cable runs in the distant zone you would typically select the 13 or 14 volt tap For cable runs in the close zone you would typically install the cable run into the 12 volt tap depending upon the wattage load and size of cable This tool tells you whether or not the 120 volt receptacle you are...

Page 4: ...he Electrical Panel to the receptacle is OK or not If it does not indicate two orange lights something is wrong with the wiring Consult an electrician 4 LX Testing Transformer Power The first test to perform will determine if power is passing through the Transformer to the low voltage taps Turn your volt meter on and place one of the probes on the lug labeled C and the other probe on the voltage t...

Page 5: ... original setting complete the reset procedure listed below 1 Hold down the GREY ENTER and DOWN button on the face pack 2 As you are holding the buttons down press the reset button on the back of the face pack 3 Release the reset button first and then release the buttons on the front A successful reset will result in 12 00 on the display You can now reprogram your LX face pack Kit Includes 26 of c...

Page 6: ... the top of the transformer This fuse does not protect the incoming voltage just the low voltage side of the transformer The LX buss fuse is located in the top wiring compartment of the LX lighting transformer Replace with a UL Listed 3AG with the following specifications 10 Amp 250V This procedure should only be performed by a licensed electrician Disconnect power from the primary and secondary U...

Page 7: ...e transformer is tested in the field 9 LX Replacement Lamp Not Working A common mistake made by many is to replace existing lamps with lamps of higher wattage than those originally installed Example If you have an FX system with a PX 600 watt transformer 25 fixtures illuminating the landscape and all of the original fixtures have 20 watt lamps in them for a total load on the transformer of 500 wat...