Boiler Connections
28
Installation Examples
(continued)
System Layout 1
Vitodens 100-W, WB1A 8-24, 8-30 with...
– one heating circuit
System Layout 1 - Alternate Option
Legend
AV
Air vent
PRV Pressure relief valve
Vitodens 100-W
Room thermostat
Heating circuit
Heating circuit pump (field
supplied)
Expansion tank
Ensure that a pressure activated
by-pass is installed. Refer to the table
for the DIP switch setting on page 38.
Please note!
The use of a low-loss header is
recommended if the water flow rate is less
than 1.7 GPM / 400 ltr/h or more than 6.2
GPM / 1400 ltr/h.
The low-loss header is available as
accessory part.
Model No.
Vitodens 100,
Max. flow rate
(GPM/ltr/h)
WB1A 8-24
6.2/1400
WB1A 8-30
6.2/1400
5
5
8
1
7
7
5
1
.3
T--T
PRV
AV
*
T--T
PRV
AV
*