background image

8

9

 

 

 

S1-A 

Automatic pre-filter  

Other soft water point 

Water heater

Other purified 

water point 

Purified water faucet 

Kitchen 

faucet 

Other purified water point 

Water purification pipeline 

Service valve 

Service valve 

Water 

meter 

Main inlet 

valve 

Soft water 

pipe 

Drain 

pipe 

Drain  

pipe 

Drain  

pipe 

Vitopure S5-D/T/Q 

Non-electric central water 

purifier 

Vitopure S4-D 

Drinking water 

purifier 

Vitopure S3-2T/3T 

Water softener 

TABLE OF CONTENT

INSTALLATION DIAGRAM

 

NOTE :

The installation diagram provides only a schematic description

of installation sequence and location. Final installation must be

and Service Manual.

 

Safety Tips

 

Safety tips ...............................................................................................................................................................................................................................................

Installation Diagram ............................................................................................................................................................................................................................

Target .......................................................................................................................................................................................................................................................
Rules and regulations .........................................................................................................................................................................................................................
Precaution for intalation maintenance and use  .......................................................................................................................................................................

 

 

 

   

 

 

 

 

 

Product information

Product description ............................................................................................................................................................................................................................
Technical data .......................................................................................................................................................................................................................................

 

 

   

 

 

Product installation

Installation environtment .................................................................................................................................................................................................................

Installation requirement ....................................................................................................................................................................................................................

First run & maintenance

First run ....................................................................................................................................................................................................................................................

 

 

 

 

   

 

 

 

 

8

9

9

9

9

10

11

12

12

13

13

SAFETY TIPS

Danger

Warning

Note

Please strictly follow these safety tips to reduce the risk of electric shock, injury, fire, 

death and property damage.

.

It indicates a potential hazard that is highly

likely to cause serious

injury or death 

It indicates a potential hazard that

could result in serious injury or

death. 

 

Ini menunjukkan bahaya yang dapat 

mengakibatkan cedera ringan atau kerusakan 

properti

This symbol is used to remind

userof the prohibited

operation steps 

 

This symbol is used to remind

user of the operation steps that

must be followed in order to

operate this product in a safe

manner

NOTE

NOTE

NOTE

TARGET

RULES AND REGULATION

National regulations on installation

Regulations on accident safety protection

Regulations on environmental protection

PRECAUTIONS BEFORE USE

 

 

 

Visual inspection

Check whether the packing box is damaged,

detached orloose.  

Check whether the device is damaged during 

transportation or loading

Open package and check

1 Non-electric central water purifier

2 straight joints

1 Installation and Service Manual

1 Quality Certificate

1 Warranty Card

This manual is intended for use only by the designated 

installer or its designated professionalsr

Precautions for installation, 

maintenance and use

The device is suitable for municipal tap water and ground 

well

Do not connect unsafe or unknown water source to the 

temperature is 1-39ºC. The device can not beinstalled on hot 

water pipeline. 

The device is installed at the rear end of the main water 

meter. If other wading device is installed in the rear pipeline 

of the water meter, please ensure to install the device in the 

front of all wading devices. 

Maintenance valves should be installed between the device 

andmain water meter and between the device and rear 

wading device. 

duringinstallation. 

The installation should be away from acid and alkaline 

substances or gases to avoid corrosion. 

If it is required to install the device outdoors, the device room 

should be built to avoid the device exposure to sun, rain, 

snow and other damages. 

being broken. 

along time or the user is absent from home. 

Remove the power adapter plug when the device is not used 

for along time or the user is absent from home. 

Please slowly turn on the main water valve before resuming 

usewhen the device is not used for a long time. Drain sewage 

and rinse the device once before re-use. 

The spare parts and wearing parts that do not compatible 

the device function. 

The installation of unauthorized components or 

When any part is replaced, it is only allowed to use 

Viessmannoriginal parts or the spare parts approved by 

Viessmann. 

thesafe operation of the device. Defective parts must be 

replaced with the original Viessmann parts

EN

EN

Summary of Contents for VITOPURE S5-D

Page 1: ...rawatan untuk produk ini ID EN NOMOR PENDAFTARAN MANUAL DAN GARANSI IMKG 2119 10 2020 VITOPURE S5 D S5 T S5 Q Non Electric Central Purifier S5 D S5 T S5 Q V I T O P U R E Please read this manual carefully before installation usage and maintenance for this product BUKU PETUNJUK MANUAL BOOK ...

Page 2: ...TAN Petunjuk Keselamatan Petunjuk Keselamatan Diagram Pemasangan Saran Peraturan dan regulasi pemasangan Perhatian sebelum pemasangan pemakaian dan perawatan Informasi produk Deskripsi produk Data teknis Petunjuk Pemasangan Hal yang peru diperhatikan pada saat pemasangan Hal yang dibutuhkan pada saat pemasangan Pemakaian Pertama Periksa kekencangan Penggunaan pertama dan pengaturan Penggunaan pert...

Page 3: ...pannya Jika perangkat ini tidak digunakan dalam jangka waktu yang lama stop kran harus ditutup atau dimatikan Jika perangkat ini sudah lama tidak digunakan untuk pemakaian pertama kali mohon buka stop kran secara perlahan pada flowmeter dan bersihkan kotoran sebelum digunakan Penggunaan spare part yang tidak kompatibel pada perangkat ini bisa menyebabkan perangkat ini tidak bekerja dengan baik Pen...

Page 4: ... dari air PAM perangkat ini melakukan saringan dengan meninggalkan sedimen karat suspensi padat dan mikroorganisme yang terkandung dalam air Dalam jangka waktu tertentu filter atau saringan perlu diganti Vitopure S5 D S5 T S5 Q Non Electric Central Purifier Vitopure S5 D S5 T S5 Q Non Electric Central Purifier ID ...

Page 5: ...ama produk Non Electric Central Purifier Model Vitopure S5 T Air masuk Air PAM dan Air Sumur Filter PP Fiber Coconut shell carbon filter Compressed activated carbon filter Kapasitas air 83 liter menit Tekanan Kerja 1 6 5 Bar Pipa air Masuk keluar DN20 Temperatur Air Masuk 1 39ºC Nama produk Non Electric Central Purifier Model Vitopure S5 Q Air masuk Air PAM dan Air Sumur Filter PP Fiber Coconut sh...

Page 6: ...n secara langsung antara inlet dan outlet Perangkat pipa dan sambungannya disarankan terpasang didinding untuk memastikan instalasi terpasang dengan kuat Sesuaikan tekanan air sesuai dengan spesifikasi perangkat dan pipa serta sambungan untuk mencegah kerusakan dan kebocoran Water inlet Water outlet Upper lid Terletak penahan di belakang penutup atas Filter element Perangkat dipasang setelah meter...

Page 7: ... filter pada perangkat ini harus diganti Matikan Stop kran utama buang sisa air pada perangkat dan saluran pipa dengan membuka kran pada salah satu titik output Lepaskan tabung filter atau penyaring dari perangkat berlawanan jarum jam Ganti tabung filter atau penyaring Buka kran pada salah satu titik output perangkat Buka stop kran utama pada inlet perangkat ini Matikan kran pada output setelah al...

Page 8: ... Drinking water purifier Vitopure S3 2T 3T Water softener TABLE OF CONTENT INSTALLATION DIAGRAM NOTE The installation diagram provides only a schematic description of installation sequence and location Final installation must be and Service Manual Safety Tips Safety tips Installation Diagram Target Rules and regulations Precaution for intalation maintenance and use Product information Product desc...

Page 9: ...e is suitable for municipal tap water and ground well Do not connect unsafe or unknown water source to the temperature is 1 39ºC The device can not beinstalled on hot water pipeline The device is installed at the rear end of the main water meter If other wading device is installed in the rear pipeline of the water meter please ensure to install the device in the front of all wading devices Mainten...

Page 10: ...ctric Central Purifier Vitopure S5 D S5 T S5 Q Non Electric Central Purifier The device is installed after the main water meter and in the front of all wading devices Relying on pressure of tap water in municipal it will be replaced with a new one 10 EN ...

Page 11: ...e Non Electric Central Purifier Model Vitopure S5 T Water Inlet Municipal Tap Water and groundwater Filter PP Fiber Coconut shell carbon filter Compressed activated carbon filter Flow Rate 83 litre minutes Working Pressure 1 6 5 Bar Water Inlet Output Pipe DN20 Water Inlet Temperature 1 39ºC Product Name Non Electric Central Purifier Model Vitopure S5 Q Water Inlet Municipal Tap Water and groundwa...

Page 12: ...smallerthan the diameter of the inlet pipe of controller to ensure that the system can provide normal water output The inlet and outlet pipes should be equipped with manualvalve It is recommended to install a bypass valve between the inlet and outlet pipes attention to measuring the height and angle No obvious stress is allowed after connections so as to avoid pipeline damage and leakage due to st...

Page 13: ...ycle and increase cleaning frequency Turn off the main water inlet valve Turn on any faucet of the cold water pipe located at the downstream of water purifier pipe release the pressure of water purifier and then turn off the faucet Unscrew the filter bottle from the device clockwise Replace filter bottle Turn on the faucet at the downstream of the device pipe Turn on main water inlet valve Turn of...

Page 14: ...14 V I T O P U R E NOTED ...

Page 15: ...15 V I T O P U R E NOTED ...

Page 16: ...N SEMANAN MEGAH KAV 7 A 7 F JAKARTA BARAT INDONESIA NEGARA PEMBUAT MADE IN CHINA CUSTOMER CARE REGIONAL OFFICE VIESSMANN SINGAPORE PTE LTD 25 INTERNATIONAL BUSINESS PARK 03 109 GERMAN CENTRE SINGAPORE 609916 VIESSMANN GROUP VIESSMANNSTRASSE 1 35108 ALLENDORF EDER GERMANY V I T O P U R E ...

Reviews: