background image

9

16

PEMASANGAN PRODUK

3-way ball valve 

Raw water pipeline 

Union 

Fixing nut 
Faucet screw 

Table top 

Quick connector 

Water 

purification 

faucet 

Pad 

Raw water pipeline 

Sambungkan ke Connector Push-in 

1. Siapkan pipa polyethylene dengan ujung yang rata.

2. Tekan pipa polyethylene ke dalam penjepit di ujung. 

Tarik pipa polyethylene untuk memastikan sudah pas.

3. Masukan gesper di antara badan konektor dan pengikat 

agar terhubung.

r

o

t

c

e

n

n

o

c

 

k

c

i

u

q

 

n

i

-

h

s

u

 

n

a

k

h

a

s

i

P

1. Tarik penjepit di antara badan konektor.

2. Tekan penjepit ke badan konektor dan keluarkan 

pipa polyethylene

PART DESCRIPTION

Vitopure S4-RO-U Drinking Water Purifier
The device consists of housing, filter element, water inlet and

outlet PE pipes, inlet 3-way ball valve, water tank, water

purification faucet and other parts.

ID

EN

PE pipe

Housing

PP fiber 

filter element

Coconut shell 

activated carbon 

filter element
Compressed carbon 

fiber filter element

Activated  FOF 

filter element

Water tank

Pure water outlet

Compressed activated 

carbon filter element

Raw water inlet

To Water tank

To RO Drinking Water Purifier

Booster pump

RO reverse osmosis membrane

Drain

Summary of Contents for Vitopure S4-RO-800G

Page 1: ...watan untuk produk ini Please read this manual carefully before installation usage and maintenance for this product NOMOR PENDAFTARAN MANUAL DAN GARANSI IMKG 2119 10 2020 VITOPURE S4 RO U VITOPURE S4 RO 800G VITOPURE S4 RO U VITOPURE S4 RO 800G V I T O P U R E ID EN BUKU PETUNJUK MANUAL BOOK ...

Page 2: ...asangan Kemasan produk unit dan aksesories yang ada dikemasan Hal yang perlu di perhatikan pada saat pemasangan Langkah langkah pemasangan Pemakain Pertama Pemeriksaan instalasi Pemasangan adaptor Penggunaan pertama Penggantian Filter 3 3 3 3 4 4 6 2 8 8 8 8 11 11 11 11 ID Service valve Main inlet valve Water meter Vitopure S1 A Automatic pre filter Service valve Water purification pipeline Kitche...

Page 3: ...t merusak bagian isolasi steker dan bisa menyebabkan kebakaran Jika perangkat ini tidak digunakan dalam jangka waktu yang lama lepaskan power adaptor dari stop kontak PERHATIAN SEBELUM PEMASANGAN PEMAKAIAN DAN PERAWATAN Perangkat ini rekomendasikan untuk sumber air dari PAM Jangan menyambungkan atau menggunakan perangkat ini dengan sumber air yang tidak direkomendasikan Perangkat ini digunakan unt...

Page 4: ...erbahaya dalam air Vitopure S4 RO U Drinking Water Purifier Vitopure S4 RO U Drinking Water Purifier Produk model Vitopure S4 RO U Air masukan Air PAM Filter PP fiber Coconute shell activated carbon Compressed activated carbon acticated carbon with scale inhibitor RO membrane Compressed activated carbon ID Kapasitas air 2 2 liter menit Tekanan kerja 1 6 5 Bar Pipa air masuk keluar DN8 Pipa bilas D...

Page 5: ...eparation membrane untuk menyaring zat berbahaya dalam air Vitopure S4 RO 800G Drinking Water Purifier Vitopure S4 RO 800G Drinking Water Purifier ID Produk model Vitopure S4 RO 800G Air masukan Air PAM Filter Compound filter RO filter Compressed activate carbond Kapasitas air 2 2 liter menit Tekanan kerja 1 6 5 Bar Pipa air masuk keluar DN10 DN8 Pipa bilas DN8 Temperatur air masuk 1 39ºC Daya mas...

Page 6: ...arts Vitopure S4 RO U Drinking Water Purifier ID Housing PP fiber filter element Coconut shell activated carbon filter element Compressed carbon fiber filter element Activated carbon FOF filter element Water tank Pure water outlet Compressed activated carbon filter element Raw water inlet To Water tank To RO Drinking Water Purifier Booster pump RO reverse osmosis membrane Drain ...

Page 7: ...ation faucet and other parts Vitopure S4 RO 800G Drinking Water Purifier Front lid Super compressed activated carbon filter element Touch induction zone Power interface Housing RO reverse osmosis membrane Folded carbon fiber composite filter element Rear part Concentrated water drain Pure water outlet Touch induction zone Tap water inlet ID ...

Page 8: ...gan di inlet air Gunakan seal tape pada ulir 3 way ball valve Hubungkan outer teeth dari 3 way ball valve ke pipa air dan kencangkan untuk mencegah kebocoran Hubungkan union 3 way ball valve ke pipa penyedia air dan kencangkan Ada bantalan penghenti air di union jangan sampai hilang Bantalan penghenti air harus berbaring datar di union untuk mencegah kebocoran 3 Pasang keran pemurnian air Aksesori...

Page 9: ...iapkan pipa polyethylene dengan ujung yang rata 2 Tekan pipa polyethylene ke dalam penjepit di ujung Tarik pipa polyethylene untuk memastikan sudah pas 3 Masukan gesper di antara badan konektor dan pengikat agar terhubung r o t c e n n o c k c i u q n i h s u p n a k h a s i P 1 Tarik penjepit di antara badan konektor 2 Tekan penjepit ke badan konektor dan keluarkan pipa polyethylene ID PE pipe ...

Page 10: ...c k c i u q n i h s u p n a k h a s i P 1 Tarik penjepit di antara badan konektor 2 Tekan penjepit ke badan konektor dan keluarkan pipa polyethylene Concentrated water outlet Table top Gasket Clean water faucet PE pipe connector Clean water faucet screw Quick connector 45 beveled end Power interface Water outlet of water purifier pure water Water inlet of water purifier tap water Raw water pipe Ex...

Page 11: ...ter Lepaskan tutup perangkat Pegang bagian atas penutup filter lalu putar berlawanan jarum jam hingga terlepas Pasang kembali Elemen Filter Setelah perawatan dan penggantian dari elemen filter putar elemen filter dan putar bagian atas tutup searah jarum jam hingga ketat Setelah selesai pembersihan atau penggantian nyalakan sakral outlet air dan periksa apakah ada kebocoran disetiap koneksi Sebelum...

Page 12: ... 13 13 14 14 Part description 15 18 18 18 18 19 19 19 19 The installation diagram provides only a schematic description of installation sequence and location Final installation must be done in the installation environment specified in the Installation and Service Manual EN Service valve Main inlet valve Water meter Vitopure S1 A Automatic pre filter Service valve Water purification pipeline Kitche...

Page 13: ...larly basis If dust is accumulated on the plug its moisture may damage the insulating part of plug and cause a fire accident If the device is not used for a long time remove power adapter Precautions for installation maintenance and use Do not connect unsafe or unknown water source to the device for filtering The device is used to pre filter tap water and the treated water is available for direct ...

Page 14: ...essure to raw water the device makes raw water pass through the reverse osmosis membrane to filter the hazardous substances contained in raw water EN Product model Vitopure S4 RO U Water inlet Municipal tap water Filter PP fiber Coconute shell activated carbon Compressed activated carbon acticated carbon with scale inhibitor RO membrane Compressed activated carbon Flow rate 2 2 liter menit Working...

Page 15: ...ology Relying on the booster pump to apply pressure to raw water the device makes raw water pass through the reverse osmosis membrane to filter the hazardous substances contained in raw water EN Product model Vitopure S4 RO 800G Inlet water Municipal tap water Filter Compound filter RO filter Compressed activate carbond Flow rate 2 2 litre minutes Working pressure 1 6 5 Bar Water inlet output pipe...

Page 16: ...ater purification faucet and other parts EN Housing PP fiber filter element Coconut shell activated carbon filter element Compressed carbon fiber filter element Activated carbon FOF filter element Water tank Pure water outlet Compressed activated carbon filter element Raw water inlet To Water tank To RO Drinking Water Purifier Booster pump RO reverse osmosis membrane Drain ...

Page 17: ...n zone Power interface Housing RO reverse osmosis membrane Folded carbon fiber composite filter element Rear part Concentrated water drain Pure water outlet Touch induction zone Tap water inlet The device consists of housing filter element water inlet and outlet PE pipes inlet 3 way ball valve water purification faucetand other parts EN ...

Page 18: ...the outer teeth of 3 way ball valve to water pipe and tighten it otherwise it may cause water leakage Connect 3 way ball valve union to water supply pipe and screw it tightly There is a water stop pad in the union do not lose it The water stop pad should lie flat in the union otherwise it may cause water leakage 3 Install a water purification faucet The faucet accessory kit contains faucet body fi...

Page 19: ...repare the PE pipe with flat ends 2 Push the PE pipe into the clamp to the end Pull the PE pipe with appropriate force to confirm the fixation 3 Insert the buckle between the connector body and the clamp to achieve firm connection Separate push in quick connector 1 Pull up the clamp between the connector body and the clamp 2 Press the clamp to the connector body and pull out the PE pipe EN PE pipe...

Page 20: ...r tap water Raw water pipe External thread 3 way ball valve Water supply pipe PRODUCT INSTALLATION Connect to push in quick connector 2 Push the PE pipe into the clamp to the end Pull the PE pipe 3 Insert the buckle between the connector body and the clamp Separate push in quick connector 1 Pull up the clamp between the connector body and the clamp 2 Press the clamp to the connector body and pull ...

Page 21: ...e normal use Gently touch the touch switch on the front panel to turn on the operation indicator and turn on water faucet outlet switch Initial use and start up Replace filter element Remove the filter element Re install the filter element The device is used to remove sand rust suspended solids microorganisms residual chlorine abnormal colors and odors other sediments contained in water If the wat...

Page 22: ...V I T O P U R E 22 NOTED ...

Page 23: ...V I T O P U R E 23 NOTED ...

Page 24: ...N SEMANAN MEGAH KAV 7 A 7 F JAKARTA BARAT INDONESIA NEGARA PEMBUAT MADE IN CHINA CUSTOMER CARE REGIONAL OFFICE VIESSMANN SINGAPORE PTE LTD 25 INTERNATIONAL BUSINESS PARK 03 109 GERMAN CENTRE SINGAPORE 609916 VIESSMANN GROUP VIESSMANNSTRASSE 1 35108 ALLENDORF EDER GERMANY V I T O P U R E ...

Reviews: