Window installation with screws
A plate is set into the window opening. The connector is fitted
through the plate, secured with screws and earthed with a pipe clip.
B
C
A
D
E
A
Fill connector
B
Screws
C
Pipe clip for earthing
D
Outlet Ø 110 mm
E
Window opening
Installation in the light well
The following types of installation are possible:
■ Into the wall
■ Into the window opening
The shortened fill and return air connectors are each inserted into a
45° bend. Insert the bend into the extension pipe that passes
through the wall or window opening.
D
C
A
E
B
A
Fill connector
B
Pipe clip for earthing
C
Extension pipe
D
Wall duct Ø 110 mm
Or
Outlet Ø 110 mm
E
45° bend
Accessories for the on-site pellet store
Baffle mat 1.42 x 1.25 m
For part no., see pricelist
The baffle mat consists of a 4.0 mm thick pressed rubber mat with
fibre-reinforcement for high strength.
Install baffle mat
B
with a clearance of at least 200 mm from the
wall opposite the fill connector. The baffle mat protects the wood pel-
lets, the brickwork and the plaster/render.
Pieces of plaster/render or wall that have been knocked off can hin-
der the pellet supply or block the ash removal from the boiler.
Standard delivery
■ Baffle mat 1.42 x 1.25 m
■ Section anchor with carbine fastening
Fuel storage
(cont.)
VITOFLEX 300-UF
Viesmann
75
5682428
7