Boiler Connections
Boiler Connections
14
Wall Mounting
(continued)
Mounting Vitodens 200 boiler
1.
Open hinged cover of the control unit
(by exerting slight pressure with
fingertip).
2.
Unlock enclosure panel by loosening
screw as illustrated.
3.
Remove front enclosure panel (lift up
and pull towards you).
4.
Loosen the two screws holding base
panel in place and remove base
panel (if still installed) towards you.
5.
Mount boiler onto the mounting
bracket.
For installation of the
mounting bracket, see
subsection entitled “Wall
mounting bracket
installation” on page 12 of
this manual.
6.
Connect boiler to the installation
fittings.
Connections
Power supply connection
Installation Instructions
Power/Pump Module
The Vitodens 200 boiler is shipped
with a Power/Pump Module, which
requires a 120 VAC power supply from
a wall receptacle.
The module contains a 120/230 VAC
step-up transformer to power the
Vitodens 200 with 230 VAC. Refer to
the Installation Instructions shipped
with the module or those contained in
this manual for wiring details.
Flue gas connection
The Vitodens 200 boiler comes with a
preinstalled vent pipe adaptor (as
shown).
Run venting system, single-wall or
coaxial, through the side wall or the
roof, taking the shortest possible route
and at a rising angle (min. 3º).
See Installation Instructions
Vitodens 200 Venting System
for details.
5285
960
v1
.2
2.
5.
1.
3.
4.
5285
960
v1
.2
Summary of Contents for Vitodens 200 WB2 11-44