Vitodens 100-W B1HE/B1KE Operating
6167 819 - 01
8
Intended Use
General Information
Product Information
Intended use presupposes that a fixed installation in
conjunction with permissible, system-specific components
has been carried out.
Commercial or industrial usage for a purpose other than
heating the building or DHW shall be deemed
inappropriate.
Any usage beyond this must be approved by the
manufacturer in each individual case.
Incorrect usage or operation of the boiler (e.g. the boiler
being opened by the system user) is prohibited and results
in an exclusion of liability. Incorrect usage also occurs if
the components in the heating system are modified from
their intended use (e.g. if the flue gas and ventilation air
paths are sealed).
The control unit is a boiler and heating circuit control unit
for the following operating modes:
Weather-compensated operation
Constant (continuous) operation
Your heating contractor will configure the operating mode
during commissioning in accordance with your heating
system. These instructions describe both operating
modes.
Weather-compensated operation
In weather-compensated operation, the supply water
temperature is controlled according to the outside
temperature.
The lower the outside temperature, the higher the supply
temperature. This means that more heat is provided for
central heating on cold days than on warmer days.
Constant operation
In constant operation the boiler provides heating water
with a constant supply temperature regardless of the
outside temperature.
Operation
The control unit is integrated into the boiler and controls
all functions of your system. The control unit is operated
via a 3.5 inch black/white screen.
A wireless (WiFi) module is integrated into the control
unit.
This means the system can also be operated remotely
via the internet using the “ViCare” app.
The boiler is only intended to be installed and operated
in sealed unvented heating systems with due attention
paid to the associated installation, service and operating
instructions. It is only designed for the heating of water
that is of potable water quality.