40
Danger
Leaking or blocked flue systems or an insuffi-
cient supply of combustion air cause life threat-
ening poisoning due to carbon monoxide in the
flue gas.
Ensure the flue system functions correctly. Aper-
tures for combustion air supply must not be able
to be closed off.
Prevent condensate drainage via a wind protec-
tor.
Fitting the front panel
1.
2.
2x
3.
4.
5.
Fig. 48
1.
Hook the bottom of the front panel into the base
rail. Secure the front panel with 2 self-tapping
screws (M 6 x 12).
2.
Insert the location stud into the front panel and
secure.
3.
Position the front panel in the lower rim and flip it
shut tightly.
4.
Secure the front panel with 2 screws (M 5 x 25).
5.
Push the front panel closed.
Commissioning and adjustment
"Vitocrossal, type CIB" service instructions and
boiler control unit operating instructions
Flue gas connection
(cont.)