7.8 Vitocell 300-V, type EVIA-A
For DHW heating
in conjunction with boilers and district heating
systems; optionally with an electric heater (accessories).
Suitable for the following systems:
■ DHW temperature up to
95 °C
■ Heating water flow temperature up to
160 °C
■ Operating pressure on the
heating water side
up to
10 bar
(1 MPa)
■ Operating pressure on the
DHW side
up to
10 bar (1 MPa)
Type
EVIA-A
EVIA-A
EVIA-A
EVIA-A
Cylinder capacity
l
160
200
300
500
DIN registration number
Applied for
Continuous output
for DHW heating from
10 to 45 °C
and a
heating water
flow
temperature of … at the heating water flow rate stated below
90 °C
kW
39
39
51
69
l/h
952
952
1247
1694
80 °C
kW
32
32
42
58
l/h
793
793
1039
1414
70 °C
kW
26
26
34
46
l/h
630
630
827
1128
60 °C
kW
19
19
25
34
l/h
461
461
607
830
50 °C
kW
11
11
15
20
l/h
270
270
358
493
Continuous output
for DHW heating from
10 to 60 °C
and a
heating water
flow
temperature of … at the heating water flow rate stated below
90 °C
kW
33
33
43
59
l/h
564
564
740
1011
80 °C
kW
26
26
34
46
l/h
444
444
584
799
70 °C
kW
18
18
24
33
l/h
313
313
413
568
Heating water flow rate
for the stated continuous outputs
m
3
/h
3.0
3.0
3.0
3.0
Standby heat loss
kWh/24
h
0.90
0.91
1.06
1.37
Dimensions
Length (Ø) a
– Incl. thermal insulation
mm
581
581
667
1022
– Excl. thermal insulation
mm
–
–
–
715
Width b
– Incl. thermal insulation
mm
605
605
744
1084
– Excl. thermal insulation
mm
–
–
–
954
Height c
– Incl. thermal insulation
mm
1189
1409
1734
1852
– Excl. thermal insulation
mm
–
–
–
1667
Height when tilted
– Incl. thermal insulation
mm
1260
1460
1825
–
– Excl. thermal insulation
mm
–
–
–
1690
Entire
weight
incl. thermal insulation
kg
60
70
105
110
Heating water capacity
l
7.4
7.4
11.0
12.9
Heating surface
m
2
1.0
1.0
1.5
1.7
Connections
(male thread)
Heating water flow and return
R
1
1
1
1
Cold water, DHW
R
¾
¾
1
1¼
DHW circulation
R
¾
¾
1
1
Energy efficiency class
A
A
A
A
Information regarding continuous output
When designing systems with the specified or calculated continuous
output, select a matching circulation pump. The stated continuous
output is achieved only if the rated boiler heating output is ≥ the con-
tinuous output.
Note
Up to 300 l cylinder capacity also available as Vitocell 300-W in
"white".
DHW cylinders
(cont.)
78
VIESMANN
VITOSOL
7
5822 440 GB
Summary of Contents for VITOCELL 100-B
Page 142: ...142 VIESMANN VITOSOL ...
Page 143: ...VITOSOL VIESMANN 143 5822 440 GB ...