SYMPTOM
POSSIBLE CAUSE
ACTION
Cabinet has no power
Cabinet is not connected to mains
or main power switch is off
Check connection to mains,
connect power cable if necessary.
Check main power switch, turn on
if necessary.
Fuse is blown
Replace blown fuse.
Cabinet does not maintain set
temperature
Air curtain is blocked, resulting
from obstruction on suction grid
Load cabinets correctly. Do not
place products or price tags in
front of airflow.
Refer to section
Loading cabinets
for cabinet loading instructions.
Air curtain is blocked, resulting
from blockage in honeycomb
Remove honeycomb and vacuum
the honeycomb.
Refer to section
Cleaning
cabinets
for cabinet cleaning
instructions.
Glass doors are not properly
closed
Make sure doors close properly.
Evaporator fans are not operating Make sure all evaporator fans are
operating. The evaporator fans
are located underneath the
bottom plates.
If the evaporator fans are not
operating, contact your nearest
service organisation.
Operating thermostat or limiter
thermostat is malfunctioning
Contact your nearest service
organisation.
5. Troubleshooting