System scheme with sub-mounting kit

M

A

B

H

G

F

E

C

D

K

Fig. 8

A

Heating circuit without mixer

B

Heating circuit with mixer (underfloor heating cir-
cuit)

C

Bypass

D

Volume balancing line

E

Plate heat exchanger for system separation

F

3-way mixer

G

Heating circuit pump

H

Flow temperature sensor

K

Temperature limiter to restrict the maximum tem-
perature of underfloor heating systems

Information regarding the heating circuit with
mixer

Install a drain & fill valve on site, in the flow of the heat-
ing circuit with mixer. This is required during commis-
sioning for filling and venting the heating circuit.
The expansion vessel integrated into the boiler can
also be used for the heating circuit with mixer.
Check whether the size of the integral expansion ves-
sel is adequate for the connected heating circuits.

Information on the underfloor heating circuit

Fit maximum temperature limiter 

K

 to the heating flow

line at least 1 m downstream of the circulation pump.

Connecting heating circuits with permeable pipework

When connecting heating systems with permeable
pipework (DIN 4726), seal off the volume balancing
line between the two heating circuits.

Note

If the volume balancing line has been removed, install
a separate expansion vessel in the regulated heating
circuit.

 

Connecting the heating circuits

 (cont.)

6131382

Summary of Contents for Sub-mounting kit

Page 1: ...Installation and service instructions for contractors VIESMANN Sub mounting kit For Vitodens 200 W and 300 W Sub mounting kit 6131382 GB 5 2019...

Page 2: ...the prevention of accidents Statutory regulations for environmental protection Codes of practice of the relevant trade associations All current safety regulations as defined by DIN EN DVGW TRGI TRF VD...

Page 3: ...onjunction with a tool Clean the sur face Dispose of component correctly Dispose of component at a suitable collec tion point Do not dispose of component in domestic waste Spare parts lists Informatio...

Page 4: ...re plumbing jig 2 3 4x 10 4 1 Fig 2 Align the drilling template below the fitting assembly of the pre plumbing jig 1 Remove the gas shut off valve 2 Mount the pipe bends with gaskets Note The pipe ben...

Page 5: ...Fig 3 1 Fit the clips to the sub mounting kit 2 Mount the gas shut off valve with gasket to the gas pipe Danger Only use the gasket from the bag for the gas shut off valve 3 Insert the gas pipe into...

Page 6: ...Secure the sub mounting kit to the wall with the screws and washers supplied 5 Only for appliances with separate DHW cylinder Mount pipe bends for the cylinder flow and return with gaskets Fitting th...

Page 7: ...or cold water line and DHW line below the sub mounting kit 2 Connect on site connection pipes to the pipe bend for the cylinder flow and return Connections on the DHW side for gas condensing combi boi...

Page 8: ...8 2 3 1 Fig 6 1 Insert gaskets 2 Fit the retaining rails for the casing 3 Hook the boiler onto the pre plumbing jig Boiler and pre plumbing jig installation instructions Fitting the boiler 6131382...

Page 9: ...with mixer G 1 Secure the twin connectors with flat gaskets to the connections of the sub mounting kit If available Fit a flow indicator accessories with flat gasket in place of the twin connector to...

Page 10: ...ing for filling and venting the heating circuit The expansion vessel integrated into the boiler can also be used for the heating circuit with mixer Check whether the size of the integral expansion ves...

Page 11: ...he union nuts Remove the balancing line with locking rings 3 Seal the connections with the plugs and union nuts supplied Lubricate the O rings with the valve grease sup plied Rotary switch S1 Rotary s...

Page 12: ...ension connected Rotary switch to 4 Note Always set the EM P1 extension subscriber num ber to a consecutive number after the EM M1 or EM MX extensions Electrical connections Connecting the mixer contr...

Page 13: ...vice instructions Danger Incorrect core assignment can result in seri ous injury and damage to the appliance Take care not to interchange wires L1 and N 2 Create the PlusBus connection Disconnect one...

Page 14: ...Flush the heating circuit under mains pressure until sound of escaping air is no longer heard Position of switch on the mixer motor Fig 14 The rotary selector on the mixer servomotor must be set to au...

Page 15: ...the flow indicator accesso ries if installed Adjusting the bypass Fig 16 A bypass is integrated into the heating circuit with mixer In the delivered condition the bypass is closed If required open the...

Page 16: ...t with B 3 9 x 13 self tap ping screw to the casing 2 Bundle the cables above the electronics module 3 Slide the casing into the fixing rails from the front 4 Secure retaining bracket with screw and r...

Page 17: ...r low loss header jF PlusBus connection for connecting to the heat generator and another accessory Declaration of Conformity We Viessmann Werke GmbH Co KG D 35107 Allendorf declare as sole responsible...

Page 18: ...18 6131382...

Page 19: ...19 6131382...

Page 20: ...Shropshire TF1 7YP GB Telephone 44 1952 675000 Fax 44 1952 675040 E mail info uk viessmann com Viessmann Werke GmbH Co KG D 35107 Allendorf Telephone 49 6452 70 0 Fax 49 6452 70 2780 www viessmann com...

Reviews: