background image

15

Viessmann products can be recycled. Components
and substances from the system are not part of ordi-
nary household waste.

For decommissioning the system, isolate the system
from the power supply and allow components to cool
down where appropriate.
All components must be disposed of correctly.

Declaration of Conformity

We, Viessmann Werke GmbH & Co. KG, D-35107
Allendorf, declare as sole responsible body that the
named product complies with the European directives
and supplementary national requirements in terms of
its design and operational characteristics.

Using the serial number, the full Declaration of Con-
formity can be found on the following website:

www.viessmann.co.uk/eu-conformity

 

Final decommissioning and disposal

5855601

 

Summary of Contents for EI2.A1000M

Page 1: ...rs VIESMANN Vitoplanar EI2 EI3 EI5 Type EI2 A180DI to EI2 A700DI EI2 A500M to EI2 A1000M EI2 A350B to EI2 A700B EI3 A500GW to EI3 A1000GW EI3 A350B to EI3 A700B EI5 A250S to EI5 A1000S Infrared heater VITOPLANAR EI2 EI3 EI5 5855601 GB 2 2020 ...

Page 2: ...appliance can also be operated by children aged 8 and older as well as by individuals with reduced physical sen sory or mental faculties or those lacking in experience and knowledge provided such individuals are supervised or have been instructed in the safe use of this appliance and any risks arising from it Regulations to be observed National installation regulations Statutory regulations for th...

Page 3: ... use Children between the ages of 3 and 8 must not plug the appliance into a wall socket regulate the appli ance clean the appliance or carry out maintenance The appliance may only be commis sioned once it has been installed The appliance must not be used in the immediate vicinity of a bathtub shower or swimming pool The appliance must not be used in small rooms inhabited by persons who cannot lea...

Page 4: ...ence Mounting the appliance on the wall 8 Position of mounting brackets 9 Vitoplanar type EI5 A250S and EI2 A180DI 9 Vitoplanar type EI_ A500_ EI2 A350DI EI2 A350B and EI3 A350B 9 Vitoplanar type EI_ A750_ EI2 A500DI EI2 A500B and EI3 A500B 10 Vitoplanar type EI_ A1000_ EI2 A700DI EI2 A700B and EI3 A700B 11 Electrical connection 12 Connection via wall junction box 12 Connection with standard plug ...

Page 5: ...ely into the room The appliance must not be used in the immediate vicinity of a bathtub shower or swimming pool All other use is deemed inappropriate Any resulting losses are excluded from the manufacturer s liability Any usage beyond this must be approved by the man ufacturer in each individual case Intended use also includes adherence to maintenance and inspection intervals Product information D...

Page 6: ...W Glass White Type Output in kW EI3 A500GW 0 5 EI3 A750GW 0 75 EI3 A1000GW 1 Infrared heater glass pure white Infrared heater as glass version Glass is an excellent emitter of radiation Vitoplanar EI3 B Bathroom Type Output in kW EI3 A350B 0 35 EI3 A500B 0 5 EI3 A700B 0 7 Infrared heater glass bathroom version Infrared heater as glass version Bathroom version with towel holder Optimised surface te...

Page 7: ...M8 x 16 Clearance dimensions Fig 2 Minimum clearances Danger If the appliance is operated without maintaining the minimum clearances flammable objects may catch fire Observe the specified minimum clearances Note When installing the appliance in bathrooms observe the safety zones according to DIN VDE 0100 part 701 Note Horizontal or vertical installation is possible Installation room requirements P...

Page 8: ... materials are used This may result in dangerous injuries and damage to the appliance Secure the appliance only with the mounting brackets for wall mounting included in the standard delivery Only use screws and rawl plugs that are suitable for the type of wall masonry con crete plasterboard etc 5 Place the infrared heater on the mounting bracket and secure with screws Please note Mechanical stress...

Page 9: ...Vitoplanar type EI5 A250S and EI2 A180DI Vertical Fig 3 Horizontal Fig 4 Vitoplanar type EI_ A500_ EI2 A350DI EI2 A350B and EI3 A350B Vertical Fig 5 Drill holes Fig 6 Position of mounting brackets 5855601 ...

Page 10: ...pe EI_ A500_ and EI2 A350DI Fig 7 Vitoplanar type EI_ A750_ EI2 A500DI EI2 A500B and EI3 A500B Vertical Fig 8 Drill holes Fig 9 Horizontal only type EI_ A750_ and EI2 A500DI Fig 10 Position of mounting brackets cont 5855601 ...

Page 11: ...11 Vitoplanar type EI_ A1000_ EI2 A700DI EI2 A700B and EI3 A700B Vertical Fig 11 Drill holes Fig 12 Horizontal only type EI_ A1000_ and EI2 A700DI Fig 13 Position of mounting brackets cont 5855601 ...

Page 12: ...st 3 mm in the permanent electrical installation in accordance with the installation regulations Note The connecting cable can be extended with a cable of type H05VV F3G 1 5 mm A direct connection to the appliance is not possible Connection with standard plug Danger A damaged connecting cable can lead to electric shock and short circuit Check the connecting cable for damage before installation Cor...

Page 13: ...I2 A500M A750M A1000M Electrical values Output W 500 750 1000 Rated voltage V 230 IP rating IP X4 Protection class I Surface temperature C Max 95 Dimensions Width mm 900 1300 1600 Height mm 630 Depth mm 30 Weight kg 14 20 25 Vitoplanar EI2 Type EI2 A350B A500B A700B Electrical values Output W 350 500 700 Rated voltage V 230 IP rating IP X4 Protection class I Surface temperature C Max 70 Dimensions...

Page 14: ...sions Width mm 900 1300 1600 Height mm 630 Depth mm 30 Weight kg 14 20 25 Vitoplanar EI5 Type EI5 A250S A500S A750S A1000S Electrical values Output W 250 500 750 1000 Rated voltage V 230 IP rating IP X4 Protection class I Surface temperature C Max 95 Dimensions Width mm 500 900 1300 1600 Height mm 630 Depth mm 26 Weight kg 6 10 14 5 18 Energy consumption data In conjunction with the Vitoplanar wir...

Page 15: ...st be disposed of correctly Declaration of Conformity We Viessmann Werke GmbH Co KG D 35107 Allendorf declare as sole responsible body that the named product complies with the European directives and supplementary national requirements in terms of its design and operational characteristics Using the serial number the full Declaration of Con formity can be found on the following website www viessma...

Page 16: ... Shropshire TF1 7YP GB Telephone 44 1952 675000 Fax 44 1952 675040 E mail info uk viessmann com Viessmann Werke GmbH Co KG D 35107 Allendorf Telephone 49 6452 70 0 Fax 49 6452 70 2780 www viessmann com 5855601 Subject to technical modifications ...

Reviews: