12
Connection to wall junction box, alternatively to stand-
ard socket
Fig. 14
Electrical connection
RTH Room thermostat (accessories)
Connection via wall junction box
Danger
Incorrect wiring can lead to serious injury from
electrical current and result in appliance dam-
age.
Connection to wall junction boxes must only be
carried out by qualified contractors.
Danger
A damaged connecting cable can lead to electric
shock and short circuit.
Check the connecting cable for damage before
installation.
On the installation side, install an omnipolar isolator
with a contact opening width of at least 3 mm in the
permanent electrical installation in accordance with the
installation regulations.
Note
The connecting cable can be extended with a cable of
type H05VV-F3G 1.5 mm².
A direct connection to the appliance is not possible.
Connection with standard plug
Danger
A damaged connecting cable can lead to electric
shock and short circuit.
Check the connecting cable for damage before
installation.
Correctly connect the supplied connecting cable with
plug to the junction box.
Commissioning and instructing the user
Commissioning and user instruction must be carried
out by the contractor performing the installation. The
operator must be instructed as to how the radiant
heater works and in particular be informed about the
minimum clearances to be observed.
Electrical connection
5855601