Fitting the cylinder temperature sensor and thermometer sensor (if supplied)
3.
4.
6.
1.
2.
5.
Fig. 7
1.
Insert the cylinder temperature sensor as far as it
will go into the opening of the clamping device.
2.
Hand-tighten the cylinder temperature sensor with
the screw provided. When doing so, hold the cylin-
der temperature sensor in place in the sensor ter-
minal until the screw is screwed in.
!
Please note
Overtightening the fixing screw may damage
the cylinder temperature sensor.
Torque: Max. 2 Nm
4.
Clamp the thermometer sensor in the clamping
bracket.
5.
Guide the thermometer cable through the groove in
the thermal insulation and the hole in the sheet
steel casing.
6.
Secure the thermometer (accessory) to the wall.
Installation instructions for wall thermometer
Installation sequence
DHW cylinders, 160 and 200 l
6150608
Installation