8
A
B
C
D
E
F
G
Fig. 2
160 to 200 l capacity
A
Protective magnesium anode with earth cable
B
DHW
C
DHW circulation
D
Clamping device for cylinder temperature sensor
E
Heating water flow
F
Heating water return
G
Cold water and drain
A
B
C
D
E
F
G
Fig. 3
300 l capacity
A
Protective magnesium anode with earth cable
B
DHW
C
DHW circulation
D
Sensor well for cylinder temperature sensor
E
Heating water flow
F
Heating water return
G
Cold water and drain
Siting information
!
Please note
The thermal insulation must not come into con-
tact with naked flames.
Exercise caution when welding and brazing.
!
Please note
To prevent material losses, site the DHW cylin-
der in a room free from the risk of frost and
draughts.
Alternatively, drain the DHW cylinder when not
in use and there is a risk of frost.
■
Allow an adequate distance from the wall to enable
the temperature controller (if supplied) to be oper-
ated.
■
Use the adjustable feet to level the DHW cylinder.
Note
Only use one or two of the adjustable feet to level the
DHW cylinder. At least one of the adjustable feet must
remain fully screwed in.
≤
35
Fig. 4
Never
extend the adjustable feet beyond a total length
of 35 mm.
Preparing for installation
Connections
6150608
Installation