GB

General notice (liability): the details of this technical documents serve for description. Consents regarding the availability of certain features or 
regarding a certain purpose always require a special written agreement.

CS and FS refrigeration units
with electronic control 
Typ SE

Operating manual
5237210-11 GB

Page No. 5237335-09 GB 

                                 Right reserved to make technical changes! Version 02.14

Please read carefully the following prior to beginning work on the refrigeration unit:

Assembly, maintenance, cleaning and repair may only be  

Work on the refrigeration unit may only be carried out if the plug

done by companies specialising in refrigeration technology. 

is removed from the power supply. Suitable warnings must be

   

posted to prevent the refrigeration unit from being restarted 

Technical changes and manipulation are prohibited. 

while work is in progress. The regulations of VDE 0105 Part 1 - for

   

work on electrical equipment must be observed.

In case of non-compliance our guarantees are void.  

   

Summary of Contents for CS 2800

Page 1: ...se read carefully the following prior to beginning work on the refrigeration unit Assembly maintenance cleaning and repair may only be Work on the refrigeration unit may only be carried out if the plu...

Page 2: ...5 Standards and regulations 6 Emergency operation 7 Defrosting 8 Serial interface 8 1 Door contact switch 9 Cleaning and maintenance of the refrigeration unit 10 Disposing of refrigerant 11 Control an...

Page 3: ...ng circulation system is opened by unauthorized personnel if there is interference in the system or if the serial number on the machine is changed or rendered unreadable 3 Area of installation The are...

Page 4: ...r source during cleaning and secure against reinsertion The cooling unit should be inspected periodically after beginning operation and if necessary cleaned Depending on requirements the intervals bet...

Page 5: ...perature The temperature setting is increased by pushing the button for at least three seconds A shorter push of the button shows the current coldroom temperature setting The temperature setting is de...

Page 6: ...efrosting time min is flashing By pressing the or the button the defrosting time can be increased or decreased by one minute at a time lt can be set between 5 and 60 minutes 13 2 3 Relative humidity L...

Page 7: ...he temperature sensor F2 Break in the temperature sensor During failure of temperature sens ons and a nominal temperature 2 C the compressor will continue to run with the last running and stand by set...

Page 8: ...ure is too high Suction and exhaust vents are blocked and the heat cannot be released Evaporator is dirty Condenser is dirty Door has been open too long Uncovered fluids are stored in the cell Defrost...

Page 9: ...for contamination and clean if necessary Check to see if condensing ventilator is running Reduce ambient temperature The display remains on but can be deleted pressing a button Check evaporator for co...

Page 10: ...85 Fresh poultry 1 1 85 90 Fresh venison 2 2 70 85 Fish Fish fresh from ice 0 1 90 100 Conserved fish 0 1 75 80 Milk and dairy products Milk 0 2 80 85 Butter 1 4 75 80 Soft cheese 0 2 80 85 Swiss che...