28
!
Please note
Only commission the appliance with a fully filled
trap.
Check that the trap has been filled with water.
Commissioning via commissioning assistant
1.
Open the gas shut-off valve.
2.
If the appliance has not been switched on yet: Turn
on the ON/OFF switch.
Call up the commissioning assistant:
1.
and
OK
should be pressed simultaneously
for approx. 4 s.
2. Use
/
to select
"b.5"
and confirm with
"OK"
.
Note
AP and
appear on the display. Confirm with
OK to start the connection with the software tool:
See chapter
"Commissioning via software tool".
3.
should be pressed for 4 s to start the com-
missioning assistant via the heat generator dis-
play.
3.
For further steps, see commissioning assistant in
the following overview.
Commissioning via software tool
Note
Apps for commissioning and service are available for
iOS and Android devices.
1.
Open the gas shut-off valve.
2. AP
and
appear on the display.
Press
OK
to carry out commissioning with the soft-
ware tool.
3.
Select
ON
and confirm with
OK
.
4.
Follow the instructions in the software tool.
Commissioning assistant
sequence
Explanations and references
Commissioning
"C.3"
Gas type
2 - Natural gas CPG
"C.5"
Flue system
1 - Open flue 60 mm
2 - Room sealed 60/100 mm
3 - Open flue 80/125 mm
4 - Room sealed 80/125 mm
"C.6"
Flue length
Given in full metres (round up if necessary)
Note
An additional length of 1 m must be factored in for every flue bend.
"C.7"
Operating mode
4 - Weather-compensated
13 - Constant operation with optional room thermostat
Note
In the event of a heat demand for central heating, plug 96 is scanned. In the
event of a DHW demand, plug X7.3/4 (outlet temperature sensor) is scanned.
After the final setting has been completed,
"End"
appears on the display.
Confirm with
"OK"
.
The commissioning is started, the flue temperature sensor test is launched
and
"Fst"
appears on the display.
The system carries out a restart.
Commissioning, inspection, maintenance
Commissioning the system
6174240