Heat pump/heating circuit settings
Setting the current operating mode
This option for setting the operating mode only affects this change of
operating mode until the next change activated by the timer program.
Operating modes of heat pump/heating circuit:
"Normal"
Heat pump and/or heating circuit are regulated to the set
standard temperature.
"Off"
The heating circuit is switched off. The heat pump will only be
activated for heating DHW (if set) and to protect the system
against frost.
"Reduced"
Heat pump and/or heating circuit are regulated to the set
reduced temperature.
"Fixed value Only for systems with heating water buffer storage unit:
regulator"
The heating water buffer storage unit will be heated
independent of outside temperature to the fixed value set by
your specialist (e.g. during low tariff times).
Heat pump 1
Current op. mode
: Standard
Normal temperature
:
20.0
Reduced temperature
:
16.0
Timer/switching times
Too warm/too cold
±
°
>> <<
STANDA
BACK
Open the programming unit flap and
press the following keys:
1.
C
for
"Programme"
.
2.
A
for
"Heat pump"
or
C
for
"Mixer 1"
.
The
"Current op. mode"
is highlighted.
3.
>>
/
<<
press until the required
operating mode is
shown.
4.
BACK
press to confirm.
Close the programming unit flap.