Saving Energy

... 

with a modern heating system

By purchasing a “modern” heating 
system, you have taken a decisive 
step towards saving energy.
Viessmann boilers operate optimally
to ensure minimum fuel consumption 
for maximum heating value - 
efficient, environmentally friendly 
and comfortable.

Your new heating system provides 
the following alternatives to save 
energy:

a well insulated hot water heating  

     boiler and domestic hot water tank

clean combustion and high energy 

     extraction

...

with proper heating

Additional energy can be saved by 
considering the following measures 
in addition to the above technical 
improvements:

proper ventilation: briefly open 

     the windows 

1

 while turning off 

     thermostats or radiator valves 

2

 

avoid excess space heating; strive 

     for a room temperature of 68º F 
     (20º C) since every 2º F (1º C) of     
     lower room temperature can save 
     up to 5% in heating costs.

proper control settings 

5

.

properly set the temperature for   

     the DHW tank 

4

 

set thermostatic zone valves 

     properly 

2

 

do not block heat transfer 

     surfaces or thermostatic zone 
     valves 

3

control use of warm water: 

     a shower generally requires less 
     water than a bath

close window shutters 

     (if applicable) during night time  
     hours.

...

with regular servicing

Regular servicing of your heating 
system 

6

 by a qualified heating 

contractor ensures energy-efficient 
and environmentally friendly 
operation.

...

with good insulation

If still searching for additional 
possibilities to save energy, 
review the insulation installed

on the heating system pipes and 

     DHW supply pipes,

on the outside walls and on the 

     roof 

7

 

between heated (shaded grey) 

     and unheated (white fill) rooms 

8

around windows 

9

.

WARNING

Ensure properly sized fresh combustion 
air supply to all fuel burning appliances, 
including the hot water heating boiler.
Tightly insulated homes require a duct 
or opening in the boiler room to allow 
outside air in for combustion. Refer to 
codes and instructions.

Operation

Summary of Contents for 7834 238

Page 1: ...ors 5712 718 v1 0 06 2011 Read and save these instructions for future reference Vitotronic 100 Model KW10B Boiler control unit for modulating temperature heating systems Part No 7834 238 VITOTRONIC 10...

Page 2: ...ure please see section entitled Important Regulatory and Safety Requirements Licensed professional heating contractor The installation adjustment service and maintenance of this equipment must be perf...

Page 3: ...ct property damage u Indicates an imminently hazardous situation which if not avoided may result in minor injury or product property damage u Helpful hints for installation operation or maintenance wh...

Page 4: ...Summer mode switch 5 Override switch 5 Power switch 5 Location of Controls 5 Starting Up the Heating System 6 Shutting Down the Heating System 6 Altering the maximum Boiler Water Temperature 7 Diagno...

Page 5: ...r DHW position w the thermostat terminal to call for heat will be disabled Units equipped with an outdoor temperature sensor and programmed for either internal outdoor reset or OpenTherm enabled therm...

Page 6: ...om thermostat or other heat demand control to desired temperature A call for heat causes the red burner status indicator to illuminate Your heating system is now ready for operation Shutting Down the...

Page 7: ...m thermostat Select an appropriate boiler water temperature based upon advice from your heating contractor The factory default setting is between 104 F and 167 F 40 C and 75 C An elevated setting betw...

Page 8: ...the pin labelled with a E using a ballpoint pen If a click can be heard the limit was tripped No fuel 1 with oil Ensure sufficient supply of oil with gas Open main gas supply valve or contact your lo...

Page 9: ...s a colorless odorless gas which may be produced during incomplete combustion of fuel and or when the flame does not receive an adequate supply of combustion air Carbon monoxide can cause severe perso...

Page 10: ...mperature can save up to 5 in heating costs proper control settings 5 properly set the temperature for the DHW tank 4 set thermostatic zone valves properly 2 do not block heat transfer surfaces or the...

Page 11: ...11 5712 718 v1 0Vitotronic 100 KW10B Operating and User s Information...

Page 12: ...cturing Company U S Inc 45 Access Road Warwick Rhode Island 02886 USA 1 800 288 0667 Fax 401 732 0590 www viessmann us com info viessmann us com Viessmann Manufacturing Company Inc 750 McMurray Road W...

Reviews: