IM-PP 724607 0815
15
Procedure for laying the XL (copper and stainless) press ring around the XL (copper and stainless) Viega ProPress fitting with minimum space requirements.
B
A
B
C
A
B
B
A
B
C
A
B
Tube
Diameter
A
B
inch mm inch mm
2½"
4
⅛
105
6
152
3"
4
⅜
111
7
178
4"
5
127
8
203
Tube
Diameter
A
B
C
inch mm inch mm inch mm
2½"
4
⅛
105
6
152 4½ 114
3"
4
⅝
111
7
178 4
⅞
124
4"
5
127
8
203 5¾ 146
V2 Actuator
V2 Actuator
V2 Pressing in tight quarters
3.3.5 Minimum space requirements for 2½" to 4" ProPress fittings
3
Wrap the actuator ring around the press fitting with the
opening facing away from you.
Close the actuator tight around the fitting.
Rotate the actuator ring until the press jaw receptacle is
facing toward you.
Properly insert press jaws and begin the press
fitting procedure.
1
2
4
Tube
Diameter
A
B
C
inch mm inch mm inch mm
2½"
6
3
/
16
157 6
15
/
16
176 2
7
/
16
62
3"
7
7
/
16
189 8
13
/
16
224 2
7
/
16
62
4"
8
1
/
16
205 10
7
/
16
265 2
7
/
16
62
Summary of Contents for Megapress
Page 27: ...IM PP 724607 0815 27 Notes ...