3
Handling
3.1
Transport
Leave the fitting in the original box, in this way spare parts important for
mounting won't get lost.
3.2
Storage
Remove the protective foil during mounting, as described in the
mounting instructions
Chapter 3.4.1 ‘Pressing onto the supply line’
3.3
Assembly information
3.3.1
Mounting instructions
The design of the tapping valve for d 63 is different from
the other pipe sizes. The pressing takes place on the
opposite side of the outlet sleeve.
Pipes must be visually inspected for the following damage before instal‐
lation:
n
Ovalities: threshold values must not be exceeded, see
tions from section: Notes on mounting’ on page 6
.
This is valid for coiled bundles as well as rods.
n
Dents
n
Cracks
n
Grooves (maximum depth 10 % of nominal wall thickness)
Only process the sections of the pipes, which do not exhibit these fea‐
tures.
The following components must be included:
n
Tapping valve
n
clamping ring
n
Locking pin for clamping ring and a replacement pin
n
Fixing bolts for tapping valve
Check scope of delivery
Handling
Geopress tapping valve
13