background image

3.2.3

Inserting the spare parts

Requirements:

n

The water supply of the cistern has been closed.

n

All parts of the existing installation you intend to replace have been
removed.

Insert the new drain valve seat into the cistern.

Push the bottom end of the drain valve seat into the drain hole of
the cistern as far as it will go.

Fasten the flap of the drain valve seat behind the holder of the filling
valve.

Insert the drain valve in the drain valve seat.

Fasten the rear of the drain valve at the drain valve seat as shown in
the illustration.

When you intend to install an electronic flush actuation or a

touchless flush plate, follow the steps described in the

instructions for use for the flush actuation or the flush plate

from this point. In this case, you do not need to carry out

the other assembly steps described in these instructions for

use.

Push the bow onto the drain valve from the left.

Handling

Drain valve set

12 from  15

Summary of Contents for 8310.0

Page 1: ...for concealed cistern 1H concealed cistern 2H retrofit to flush plate Visign for Style or Visign for More Model Year built 8310 0 from 07 2007 en_INT Drain valve set Instructions for Use...

Page 2: ...Drain valve set 2 from 15...

Page 3: ...ed version 5 2 Product information 6 2 1 Area of application 6 2 2 Product description 7 3 Handling 8 3 1 General mounting instructions 8 3 2 Assembly 8 3 2 1 Setting the flush volume 8 3 2 2 Removing...

Page 4: ...The installation of Viega products must take place in accordance with the general rules of engineering and the Viega instructions for use 1 2 Labelling of notes Warning and advisory texts are set asid...

Page 5: ...d or in Germany e g DIN DVGW Some passages in the text may refer to technical codes in Europe Germany These should serve as recommendations in the absence of corresponding national regulations The rel...

Page 6: ...l 8351 1 Model 8352 1 Model 8354 1 Model 8357 1 The drain valve set can be inserted in one of the following WC elements or WC modules n Viegaswift Model 8000 Model 8000 90 Model 8000 99 Model 8032 Mod...

Page 7: ...and large flush volumes are actuated by pressing the small or the large button in the flush plate n Immediate re flushing is possible because the cistern is not emptied completely n The small flush vo...

Page 8: ...the drain valve set set the flush volume at the drain valve as follows Set the small flush volume at the slide control at the side of the overflow pipe n Slide control in top position approx 3 litres...

Page 9: ...correspond to the steps shown in the following To remove the existing installation proceed as follows Remove the flush plate Pull the plate off the wall as straight as possible Loosen the support at...

Page 10: ...aft Use a flat blade screwdriver to turn the lock of the mechanism anti clockwise through 90 to release the mechanism Remove the mechanism from the installation shaft and dispose of it Remove the bow...

Page 11: ...Remove the drain valve and dispose of it Loosen the flap of the drain valve seat Remove the drain valve seat and dispose of it Handling Drain valve set 11 from 15...

Page 12: ...behind the holder of the filling valve Insert the drain valve in the drain valve seat Fasten the rear of the drain valve at the drain valve seat as shown in the illustration When you intend to instal...

Page 13: ...he bow of the drain valve in the clip of the mechanism Turn the mechanism s lock by 90 in a clockwise direction The mechanism is locked Insert the cover When you intend to mount a new flush plate foll...

Page 14: ...90 turn Screw the actuating rods into the threaded holes of the mechanism Shorten the actuating rods with a knife The top actuating rod must project 11 mm beyond the upper edge of the tiles The bottom...

Page 15: ...e basic panel press in below 3 3 Disposal Separate the product and packaging materials e g paper metal plastic or non ferrous metals and dispose of in accordance with valid national legal requirements...

Reviews: