3.2 Commissioning
CAUTION!
Risk of crushing from operating the press machine
without press jaw.
If no press jaw is inserted, your fingers can become crushed in the
danger zone of the press machine.
■
Never use the press machine without the press jaw inserted.
■
Do not place your fingers in the danger zone.
CAUTION!
Damage to device due to incomplete locking of the
retaining bolt.
If the retaining bolt is not fully inserted and locked, the cylinder may
tear during the pressing.
■
Make sure the retaining bolt is closed before initiating a pressing.
▶
Check the scope of delivery.
▶
See image
7
. Insert the fully charged lithium ion rechargeable battery into the
mounting bracket on the handle.
Press the battery level check button to check the battery charge level.
The display disappears as soon as the button is released again.
▶
See image
8
. Turn the retaining bolt lever of the retaining bolt by 180° to
release it from the lock position.
▶
Pull out the retaining bolt.
▶
See image
9
. Insert the press jaw into the press jaw fixture of the cylinder head.
Push the retaining bolt back to secure the jaw once it is inserted.
The figures show the typical use of a press jaw. Use the hinged actua-
tor jaws in the same way.