Mark the insertion depth.
Place the press jaw onto the press machine and push the retaining
bolt in until it clicks into place.
INFO! Observe the press tool instruction manual.
Open the press jaw and place at a right-angle onto the connector.
Check the insertion depth using the marking.
Ensure that the press jaw is placed centrally on the bead of the
press connector.
Carry out the pressing process.
Open and remove the press jaw.
ð
Connection is pressed.
3.2.4
Leakage test
The installer must perform a leakage test before commissioning.
Carry out this test on a system that is finished but not yet covered.
Handling
Easytop Inox slanted seat valve (free flow valve) with SC-Contur
19 from 20