Serial Communications
Vidikron PlasmaView Owner’s Operating Manual
47
PRE
L
IMINAR
Y
Gain/Offset
(Green)
0 (min) ...
70 (max)
DFH
80H
60H
7FH
04H
01H
02H
D8H ...
1EH
(Gain)
D8H ...
1EH
(Offset)
F5H (=0/0) ...
81H (=70/70)
Gain/Offset
(Blue)
0 (min) ...
70 (max)
DFH
80H
60H
7FH
04H
01H
03H
D8H ...
1EH
(Gain)
D8H ...
1EH
(Offset)
F6H (=0/0) ...
82H (=70/70)
Cinema
Mode
ON
OFF
DFH
80H
60H
C1H
01H
01H
02H
82H
83H
Image
Preset
STANDARD
DFH
80H
60H
0AH
01H
01H
CBH
PRESET1
DFH
80H
60H
0AH
01H
02H
CCH
PRESET2
DFH
80H
60H
0AH
01H
03H
CDH
FACTORY
DFH
80H
60H
0AH
01H
04H
CEH
PRESET3
DFH
80H
60H
0AH
01H
05H
CFH
Gamma
2.1
2.2
2.3
2.4
DFH
80H
60H
13H
02H
01H
00H
01H
02H
03H
D5H
D6H
D7H
D8H
Dither
MODE1
MODE2
DFH
80H
60H
0CH
01H
01H
02H
CDH
CEH
Black Level
NORMAL
STEP1
STEP2
DFH
80H
60H
35H
01H
01H
02H
03H
F6H
F7H
F8H
ICC (Red)
0 (Y) ... 64 (M)
DFH
80H
60H
0DH
07H
00H ... 40H for each color component, followed by 00H.
Calculate the checksum as described in
Serial
Command/Response Messages
on page 45.
Example:
20H 20H 20H 20H 20H 20H 00H 93H
(R) (G) (B) (Y) (M) (C)
sets ICC to 32 for all six color components.
ICC (Green)
0 (Y) ... 64 (M)
ICC (Blue)
0 (Y) ... 64 (M)
ICC (Yellow)
0 (Y) ... 64 (M)
ICC
(Magenta)
0 (Y) ... 64 (M)
ICC (Cyan)
0 (Y) ... 64 (M)
ICC Reset All
--
00H 00H 00H 00H 00H 00H 01H
D4H
Bass
0 (min) ...
+26 (max)
DFH
80H
60H
7FH
03H
05H
03H
F3H ...
0DH
3CH (=0) ...
56H (=+26)
Treble
0 (min) ...
+26 (max)
DFH
80H
60H
7FH
03H
05H
04H
F3H ...
0DH
3DH (=0) ...
57H (=+26)
Balance
-22 (L) ...
+22 (R)
DFH
80H
60H
7FH
03H
05H
02H
EAH ...
16H
32H (=-22) ...
5EH (=+22)
Table 6-1. Serial Commands (continued)
Function
Command
Command
Data
Length
(Bytes)
Data
Checksum