V-Tap VoIP Manual EN v2.7 Oct 2018 © 2017-2018 Vidicode 29
MAC Address
The Media Access Control (MAC) address of the device is a unique
identifier to communicate over an Ethernet network. The address
cannot be changed.
3.3.12
App Special Flags
App Special Flags
This parameter represents a mixture of internal options and/or
commands.
When filled in as a numeric value, the used bits are all on/off
switches as shown below. The result of the sum of the used bits must
be entered as a decimal number. For example, settings bit3 and bit12
results in the value 8+4096 = 4104.
bit0 (+1) : Disable Auto Delete function when SD card is almost full.
bit1 (+2) : Enable SD Power Save Mode (slow clock during idle time).
bit2 (+4) : Disable initializing the IP-stack instead of Tunnel Close.
bit3 (+8) : VLAN tags are not removed from the mirror port.
bit4 (+16) : Force Half Duplex on all LAN ports, except a mirror port.
bit5 (+32) : Force 10 Mbps on all LAN ports, except a mirror port.
bit6 (+64) : Set time as Daylight Saving Time for PCAP files.
bit7 (+128) : Disable Daylight Saving Time Correction in the NTP function.
bit8 (+256) : Enable CPU Overclocking (10 % faster).
bit9 (+512) : Disable CPU Cash Controller (20 % slower).
bit10 (+1024) : CPU running on overclocking (5% faster).
bit11 (+2048) : Disable USB function, so no HID recognition (saves power).
bit12 (+4096) : Disable USB sleep function 10 minutes after start-up.
bit13 (+8192) : Disable Tunnel disconnection after buffer-full error (no SD).
The App Special Flags field can also be used to enter commands for
extra settings and features:
"FACTORY"
= Factory settings! The IP address goes back to 192.168.55.66.
".CS"
= Show all current SD file-counters in the App Special Flags.
Note: The Read file-counter on 0 will resend all files again!
".CR<numb>" = Set SD card Read file-counter from 0 till 32767.
".CW<numb>" = Set SD card Write file-counter from 0 till 32767.
".CD<numb>" = Set SD card Delete file-counter from 0 till 32767.