Optilog4Me IP Manual © Vidicode 2004
20
The setting options for the administrator
are accessed by pressing the "Menu"
function key and entering the
"Administrator password" service code
(
Menu 2
).
The following settings can be changed in sequence by your
administrator: (Factory setting is printed in bold type)
Mode:
Operating mode used for the call
recorder:
Start recorder
, for recording
from start Trader recorder, for continuous
recording Recorder for threatening calls,
for recording from the beginning Third-
party monitoring, for recording at a
central point
Method:
Type of connection to telephone:
VOX
handset
, for connection to an optiset E via
handset connection lead or headset-plus-
adapter
•
VOX microphone
•
VOX lead
•
Analog lead, for connection to an
analog telephone
Signal setting:
Settings for signal strength which
starts/stops the recording with the "VOX
handset" (
9/ 8, B4/A5
). The initial and idle
level is changed using the
"forward/reverse" playback keys. The
value can be displayed via the "play" key.
The star (
) key sets amplification for
sides B and A. The hash key (#) is used to
select the side. Exit this setting mode via
the A side.