SLAVE MODE - SW2.4

This set up concerns the answering mode of the video monitor when there is more than one unit (max 4) in the same 

apartment. OFF (default) = during a call, only the video monitor with extension 1 (master) will show the video. ON = the 

video monitor will be switched on independently of the extension address: in this case the video monitor must be sup-

plied locally using a power supply Art. 2321 and connecting respectively 

BUS+

 to terminal 

+VAUX

 and 

BUS–

 to terminal 

GND

 on the connection terminals (the local power supply is required for each black & white slave videophone or starting from the 

third slave videophone when they are all colour videophones).

If you set for one slave videophone, you must set ON the same switch also for the relevant master videophone.

CONNECTION TERMINALS SIGNALS

BUS1

Bus input

BUS2

Bus input

GND

Ground

12M

+12Vdc power supply input (Art. 323/12 or Art. AMR2-

12) for version with Memory Board option or auxiliary 

power supply input (to be used when two or more slave 

monitors are ringing together with the switch 4 of 

SW3

 

is set to ON)

GND

Ground

VA

+30Vdc power supply input (Art.  2321) to be used 

when two or more slave monitors are ringing togeth-

er with the switch 4 of 

SW3

 set to ON

C

Dry contact. Internally linked to 

NO

 

when the 

 button is pressed. 

Max 35Vdc, 

50mA

NO

Dry contact. Internally linked to 

C

 

when the 

 button is pressed. 

–DOL

Auxiliary LED power supply input (ground)

+DOL

Auxiliary LED power supply input (+12Vdc)

GND A

Ground output for use in combination with 

AL

 & 

LB

 

active low inputs

LB

Local bell input (active low)

AL

Alarm input (not implemented yet)

TECHNICAL SPECIFICATION
Housing/Mounting:

 

6300 Series Videophones 

 

surface mount

Push buttons:

 

Yes, 4

Programming:

 

Yes, carried out by the buttons and 

the dip-switches located on the rear 

of the videophone

Controls:

 

Call tone volume, picture hue, 

brightness and contrast

Power Supply:

 

Supplied by the BUS line

Power consumption:

  

Stand-by:  0.2mA

 

Operating: 115mA

Working Temperature:

  -10 +50 °C

MEMORY BOARD

This device is also available in the version with memory board (Art. 6388/VM).

If you have that version, please refer to the 

“6200, 6300, 6400 and 6700 Series Memory Board” 

user manual (in 

English and Italian) for installation and use.

The manual is available for download: click/tap or scan the QR code.

ON 

1 2 3

4

SW2.4

Art. 6388 

 3.5" colour display videophone 

Summary of Contents for ESVK-1/6388

Page 1: ...2 19 VIDEOKIT ESVK 6388 SERIES 2 Wire bus one way two way videokit Installation handbook 6388 We recommend This equipment is installed by a Competent Electrician Security or Communications Engineer ESVK ESVKX ESVKC Rev 0 1 ...

Page 2: ...phone address extension numberofringsetc thevideophonemustbedisconnectedfrom the relevant connection board then after a few seconds reconnected again to allow the recognizing of the new setting All diagrams shown are valid for B W or colour systems with surface or flush mount door station ADDRESSES 1 12 TABLE FOR DIP SWITCH BANKS WITH ON POSITION UP OFF ON 1 2 3 4 5 6 7 8 ON 1 1 2 3 4 5 6 7 8 ON 2...

Page 3: ...composed of 1 Art 4333 1 1 button camera unit 1 Art 4851 Flush mounting box 1 Colour videomonitor Art 6388 1 Power supply Art 2321 ESVK 1S 6388 surface mounting 1 Outdoor station composed of 1 Art 4333 1 1 button camera unit 1 Art 4881 Surface mounting box 1 Colour videomonitor Art 6388 1 Power supply Art 2321 TWO WAY VERSIONS ESVK 2 6388 flush mounting 1 Outdoor station composed of 1 Art 4333 2 2...

Page 4: ...ing box 1 Colour videomonitor Art 6388 1 Power supply Art 2321 1 Card format fob Art 955 C 2 Tag format fobs Art 955 T ESVKX 1S 6388 surface mounting 1 Outdoor station composed of 1 Art 4333X 1 1 button camera unit 1 Art 4881 Surface mounting box 1 Colour videomonitor Art 6388 1 Power supply Art 2321 1 Card format fob Art 955 C 2 Tag format fobs Art 955 T TWO WAY VERSIONS ESVKX 2 6388 flush mounti...

Page 5: ...t 6388 1 Power supply Art 2321 1 Power supply converter Art 2322 ESVKC 1S 6388 surface mounting 1 Outdoor station composed of 1 Art 4333 1 1 button camera unit 1 Art 4800M Codelock module 1 Art 4882 Surface mounting box 1 Colour videomonitor Art 6388 1 Power supply Art 2321 1 Power supply converter Art 2322 TWO WAY VERSIONS ESVKC 2 6388 flush mounting 1 Outdoor station composed of 1 Art 4333 2 2 b...

Page 6: ...ck you can then use up to 300m cable in the block Assuming you are using another 50 meters cable to get from the first to the second block in the second you can use 400 100 50 250m It is important that the video intercom system cables do not run with mains or other high power cables Noise from such cables electromagnetic interference may cause noises on audio video and lost functionality In cases ...

Page 7: ...46 Monte Giberto FM Phone 39 0734 631669 Fax 39 0734 631669 Autore Data modifica Data creazione Title Notes Titolo Note Cod File Foglio 1 1 Marco Rongoni 02 07 2014 02 07 2014 Art 2321 BUS Art 317N Art 3686 Art SL5488N Art 6286 Art KRV86 Max 200m Max 200m Max 200m Max 200m Max 200m Max 400m Using Cable CM2 Usando Cavo CM2 Using Cable CM2 Usando Cavo CM2 Using Cable CM2 Usando Cavo CM2 VX2300CL dwg...

Page 8: ... balance circuit with BALANCE control The enslavement relay to enable the electric lock 3 contacts common normally open and normally closed It can work also as capacitor discharge to supply directly the electric lock The call buttons from 1 to a maximum of 2 depending on the module version The illumination LEDs for the card name holder The camera comprised of illumination LEDs MODULE DETAILS A Cam...

Page 9: ...t will switch OFF at the end of the programmed door opening time PROGRAMMING The programming consists of the following settings Unit ID 1 8 Door Opening Time 1 2 5 or 10 seconds Conversation Time 1 or 2 minutes Addressing order of the buttons Main camera selection The settings are carried out through the 8 way dip switch reference J on Fig 2 accessible from the rear side of the module UNIT ID Swit...

Page 10: ...f an already programmed tag is placed in front of the tag reader BIP BIP BIP Note the external module emits three high pitched beeping sounds to indicate that its memory is full 50 tags maximum In this instance it is not possible to program new tags BIP BIP BIP 6 To exit programming mode place the master tag in front of the tag reader or wait 10 seconds after the most recent programming operation ...

Page 11: ...external module s housing HOW TO CONNECT AN ELECTRIC LOCK The door open relay can operate either as dry contact or capacitive discharge mode In dry contact operation mode the relay works in a traditional way a power supply or a power source is needed to operate the lock 12 24Vac dc 2A max and activation lasts according to the door opening time programmed In capacitive discharge operation mode the ...

Page 12: ...sary Max 12Vdc 150mA EB2 Expansion button input 2 EB1 Expansion button input 1 GND Ground BUS BUS Connection terminals BUS PTE Push to exit active low input GND Ground GND NO Door open relay normally open contact Max 12 24 Vac dc 2A C Door open relay common contact C Electric lock capacitor discharge output VAUX 35Vdc power supply input if used the module is powered locally and not from the BUS NC...

Page 13: ...NS FOR INSTALLATION In order to achieve the best results from the schematics described it is necessary to install only original VIDEX equipment strictly keeping to the items indicated on each schematic and follow these General Directions for Installation The system must be installed according to national rules in force in any case the running of cables of any intercom unit must be carried out sepa...

Page 14: ...re enter the existing time then press ENTER Melody The system is ready to use the red LED will be off PROGRAMMING NOTES After pressing enter following a command press ENTER a fur ther twice to exit the programming menu RETURN SYSTEM TO PRESET ENGINEER S FACTORY CODE Turn off power to code lock Keep ENTER button pressed while turning the power back on Release ENTER button The engineer s code is now...

Page 15: ...ally closed contact Max 24Vac dc 3A NO3 Relay 3 normally open contact C3 Relay 3 common contact NC2 Relay 2 normally closed contact NO2 Relay 2 normally open contact C2 Relay 2 common contact NC1 Relay 1 normally closed contact NO1 Relay 1 normally open contact C1 Relay 1 common contact 12 24Vac dc power input CLEANING OF THE PLATE Use a clean and soft cloth Use moderate warm water or non ag gress...

Page 16: ...dbook 4000 Series Surface and flush mounting door station installation EXAMPLE INSTALLING A FOUR MODULE OUTDOOR STATION H G H Y G C F E D B A C L H L P O N M H M M C Q P C D W N N C H fig 1 fig 8 fig 4 fig 5 fig 6 fig 7 fig 3 fig 10 fig 11 fig 15 fig 12 fig 16 fig 13 fig 17 fig 14 fig 18 fig 2 fig 9 ...

Page 17: ...and is working correctly move back the module support frames carefully fix them to the surface box using the screwdriver provided P torx end and the pin machine torx screws Q Fig 11 Note do not over tighten the screws more than is necessary INSTALLING A FLUSH MOUNTING DOOR STATION When flush mounting and the number of modules is greater than 3 the required back boxes need to be linked together bef...

Page 18: ...rvice push button When pressed it links internally the terminals C and NO on the connection terminals Privacy ON OFF push button To enable the function press this button when the videophone is in stand by The service is automatically disabled when the programmed time expires the privacy duration time can be programmed or manually by pressing again the button Activate bus relay board Art 2305 push ...

Page 19: ...e Not available in some LCD versions S3 Bus termination switch lower position BUS termination active upper po sition BUS termination disabled PROGRAMMING The videophone setup consists of the following settings Number of rings Melody selection Privacy duration Unit address 1 127 switches 1 to 7 of SW1 Bus Termination open or close S3 switch Intercommunication mode between apartments or within apart...

Page 20: ...posi tion to enable the bus termination In case of more units intercoms videophones or video monitors in a parallel connection bus wires are connected to the terminals of the first unit then from this to the second and so on up to 4 units max the BUS termination must be enabled only for the last unit in the chain while on all other units it must be set to disabled INTERCOMMUNICATION MODE SW2 1 Thi...

Page 21: ...ringing together with the switch 4 of SW3 is set to ON GND Ground VA 30Vdc power supply input Art 2321 to be used when two or more slave monitors are ringing togeth er with the switch 4 of SW3 set to ON C Dry contact Internally linked to NO when the button is pressed Max 35Vdc 50mA NO Dry contact Internally linked to C when the button is pressed DOL Auxiliary LED power supply input ground DOL Auxi...

Page 22: ...e F Fig 4 If you use the flush mounting box 503 embed it into the wall vertically at approx 140cm from the finished floor and the base 4 Following Fig 4 make the holes B insert the wall plugs C and fix the base with the screws D feeding the wires E through the hole F If you have used the box 503 fix the base to the wall through the holes G using the screws D 5 As shown in Fig 5 connect the wires t...

Page 23: ...o the mains through an all pole circuit breaker which shall have contact separation of at least 3mm in each pole and shall disconnect all poles simultaneously The all pole circuit breaker shall be placed for easy access and the switch shall remain readily operable POWER SUPPLY INSTALLATION Remove the terminal side covers by unscrewing the retaining screws Fix the power supply to a DIN bar or direc...

Page 24: ... power source This unit can be used to supply peripher als such as the Art 4800 or Art 4800M without the need for an additional power supply Please note The peripherals must not require more than 100mA CONNECTION TERMINALS BUS BUS line inputs BUS 12V 12Vdc 100mA output 12V 0V TECHNICAL SPECIFICATION Housing Mounting Plastic box 50x60x20mm direct wall mounting Push buttons N A Programming N A Contr...

Page 25: ... 5 EB1 Switch 7 ON Connect to EB1 terminalof Art 4333 Connect to GND terminalof Art 4333 Connecttoterminal 1 ofthebuttonexpansionmodule Connecttoterminal 2 ofthebuttonexpansionmodule Connecttoterminal 3 ofthebuttonexpansionmodule Connecttoterminal 4 ofthebuttonexpansionmodule Connecttoterminal 5 ofthebuttonexpansionmodule Connect to 1C terminal of Art 4842 Art 4843 Art 4844 or Art 4845 RED BLACK F...

Page 26: ...E terminal of Art 4333 Connect to terminal 1 of the button expansion module Connect to terminal 2 of the button expansion module Connect to terminal 3 of the button expansion module Connect to terminal 4 of the button expansion module Connect to terminal 5 of the button expansion module Connectto 1C terminalofArt 4842 Art 4843 Art 4844 or Art 4845 Red Black Connect to GND terminal ofArt 4333 Fig 3...

Page 27: ...ny other device connected to the system it is necessary to restart the system power off then power on Local Bell 4 6 5 3 2 1 ON Unit ID 8 7 Art 4333 1 1 1 5 4 3 8 7 6 ON 2 1 4 3 ON 2 1 Videophone Extension N BUS1 BUS2 GND 12VM GND DOL AL LB GND LB AL DOL VAUX C NO S3 Term ON Term OFF 1 1 ART 6388 Videx Electronics S p A Via del Lavoro 1 63846 Monte Giberto FM Phone 39 0734 631669 Fax 39 0734 63166...

Page 28: ... off then power on Local Bell 4 6 5 3 2 1 ON Unit ID 8 7 Art 4333 2 1 Local Bell 1 2 Local Bell 5 4 3 8 7 6 ON 2 1 4 3 ON 2 1 Videophone Extension N BUS1 BUS2 GND 12VM GND DOL AL LB GND LB AL DOL VAUX C NO S3 Term ON Term OFF 2 1 ART 6388 5 4 3 8 7 6 ON 2 1 4 3 ON 2 1 Videophone Extension N BUS1 BUS2 GND 12VM GND DOL AL LB GND LB AL DOL VAUX C NO S3 Term ON Term OFF 1 1 ART 6388 Videx Electronics ...

Page 29: ... connected to the system it is necessary to restart the system power off then power on 4 6 5 3 2 1 ON Unit ID 8 7 Art 4333 1 1 1 MOV Art 4800 12V BUS Art 2322 Local Bell 5 4 3 8 7 6 ON 2 1 4 3 ON 2 1 Videophone Extension N BUS1 BUS2 GND 12VM GND DOL AL LB GND LB AL DOL VAUX C NO S3 Term ON Term OFF 1 1 ART 6388 Videx Electronics S p A Via del Lavoro 1 63846 Monte Giberto FM Phone 39 0734 631669 Fa...

Page 30: ...l 5 4 3 8 7 6 ON 2 1 4 3 ON 2 1 Videophone Extension N BUS1 BUS2 GND 12VM GND DOL AL LB GND LB AL DOL VAUX C NO S3 Term ON Term OFF 2 1 ART 6388 5 4 3 8 7 6 ON 2 1 4 3 ON 2 1 Videophone Extension N BUS1 BUS2 GND 12VM GND DOL AL LB GND LB AL DOL VAUX C NO S3 Term ON Term OFF 1 1 ART 6388 12Vac SE Push to Exit 4 6 5 3 2 1 ON Unit ID 8 7 Art 4333 2 1 MOV Art 4800 12V BUS Art 2322 1 2 BUS Art 2321 Vid...

Page 31: ...the system power off then power on 4 6 5 3 2 1 ON Unit ID 8 7 Art 4333 1 1 1 BUS BUS GND LB AL Art 3183 VIDEX S1 Phone No Extension N 1 2 Art 2305 External Camera 12Vdc 150mA MAX Art 2305 Service 2 Service 1 Local Bell 5 4 3 8 7 6 ON 2 1 4 3 ON 2 1 Videophone Extension N BUS1 BUS2 GND 12VM GND DOL AL LB GND LB AL DOL VAUX C NO S3 Term ON Term OFF 1 1 ART 6388 Videx Electronics S p A Via del Lavoro...

Page 32: ...art the system power off then power on 1 2 Videx Electronics S p A Via del Lavoro 1 63846 Monte Giberto FM Phone 39 0734 631669 Fax 39 0734 631669 www videx it info videx it Autore Data modifica Data creazione Title Notes Titolo Note Cod File Foglio 1 1 Roberto Gambini esvk 63h 006 dwg 20 02 2017 20 06 2018 BUS Art 2321 12Vdc Push to Exit 4 6 5 3 2 1 ON C BUS BUS PTE GND GND NO NC VAUX C Unit ID V...

Page 33: ...OL AL LB GND LB AL DOL VAUX C NO S3 Term ON Term OFF 3 1 ART 6388 5 4 3 8 7 6 ON 2 1 4 3 ON 2 1 Videophone Extension N BUS1 BUS2 GND 12VM GND DOL AL LB GND LB AL DOL VAUX C NO S3 Term ON Term OFF 4 1 ART 6388 Local Bell Local Bell Local Bell 5 4 3 8 7 6 ON 2 1 4 3 ON 2 1 Videophone Extension N BUS1 BUS2 GND 12VM GND DOL AL LB GND LB AL DOL VAUX C NO S3 Term ON Term OFF 1 1 ART 6388 5 4 3 8 7 6 ON ...

Page 34: ...c 4 6 5 3 2 1 ON C BUS BUS PTE GND GND NO NC VAUX C Unit ID VID2 GNDV V2 EB2 EB1 GND 8 7 Art 4333 0 2 5C 4 1 3C 4C 3 2 2C 1C 5 2C 3C 4C 5C 1C Art 4843 Art 125 1 5KOhm 1W 12Vdc Push to Exit 4 6 5 3 2 1 ON C BUS BUS PTE GND GND NO NC VAUX C Unit ID VID2 GNDV V2 EB2 EB1 GND 8 7 Art 4333 0 1 5C 4 1 3C 4C 3 2 2C 1C 5 2C 3C 4C 5C 1C Art 4843 Art 125 1 5KOhm 1W Push to Exit Videx Electronics S p A Via de...

Page 35: ... ON 2 1 4 3 ON 2 1 Videophone Extension N BUS1 BUS2 GND 12VM GND DOL AL LB GND LB AL DOL VAUX C NO S3 Term ON Term OFF 3 1 ART 6388 Local Bell Local Bell Local Bell 5 4 3 8 7 6 ON 2 1 4 3 ON 2 1 Videophone Extension N BUS1 BUS2 GND 12VM GND DOL AL LB GND LB AL DOL VAUX C NO S3 Term ON Term OFF 1 1 ART 6388 5 4 3 8 7 6 ON 2 1 4 3 ON 2 1 Videophone Extension N BUS1 BUS2 GND 12VM GND DOL AL LB GND LB...

Page 36: ...rt the system power off then power on 1 4 Videx Electronics S p A Via del Lavoro 1 63846 Monte Giberto FM Phone 39 0734 631669 Fax 39 0734 631669 www videx it info videx it Autore Data modifica Data creazione Title Notes Titolo Note Cod File Foglio 4 1 Roberto Gambini esvk 63h 007a dwg 09 04 2018 20 06 2018 BUS Art 2321 12Vdc Push to Exit 4 6 5 3 2 1 ON C BUS BUS PTE GND GND NO NC VAUX C Unit ID V...

Page 37: ...L AL LB GND LB AL DOL VAUX C NO S3 Term ON Term OFF 3 1 ART 6388 5 4 3 8 7 6 ON 2 1 4 3 ON 2 1 Videophone Extension N BUS1 BUS2 GND 12VM GND DOL AL LB GND LB AL DOL VAUX C NO S3 Term ON Term OFF 4 1 ART 6388 Local Bell Local Bell Local Bell 5 4 3 8 7 6 ON 2 1 4 3 ON 2 1 Videophone Extension N BUS1 BUS2 GND 12VM GND DOL AL LB GND LB AL DOL VAUX C NO S3 Term ON Term OFF 1 1 ART 6388 5 4 3 8 7 6 ON 2...

Page 38: ...L AL LB GND LB AL DOL VAUX C NO S3 Term ON Term OFF 7 1 ART 6388 5 4 3 8 7 6 ON 2 1 4 3 ON 2 1 Videophone Extension N BUS1 BUS2 GND 12VM GND DOL AL LB GND LB AL DOL VAUX C NO S3 Term ON Term OFF 8 1 ART 6388 Local Bell Local Bell Local Bell 5 4 3 8 7 6 ON 2 1 4 3 ON 2 1 Videophone Extension N BUS1 BUS2 GND 12VM GND DOL AL LB GND LB AL DOL VAUX C NO S3 Term ON Term OFF 5 1 ART 6388 5 4 3 8 7 6 ON 2...

Page 39: ... LB AL DOL VAUX C NO S3 Term ON Term OFF 11 1 ART 6388 5 4 3 8 7 6 ON 2 1 4 3 ON 2 1 Videophone Extension N BUS1 BUS2 GND 12VM GND DOL AL LB GND LB AL DOL VAUX C NO S3 Term ON Term OFF 12 1 ART 6388 Local Bell Local Bell Local Bell 5 4 3 8 7 6 ON 2 1 4 3 ON 2 1 Videophone Extension N BUS1 BUS2 GND 12VM GND DOL AL LB GND LB AL DOL VAUX C NO S3 Term ON Term OFF 9 1 ART 6388 5 4 3 8 7 6 ON 2 1 4 3 ON...

Page 40: ... restart the system power off then power on 1 3 Videx Electronics S p A Via del Lavoro 1 63846 Monte Giberto FM Phone 39 0734 631669 Fax 39 0734 631669 www videx it info videx it Autore Data modifica Data creazione Title Notes Titolo Note Cod File Foglio 3 1 Roberto Gambini esvk 63h 008 dwg 09 04 2018 13 04 2018 BUS Art 2321 12Vdc Push to Exit 4 6 5 3 2 1 ON C BUS BUS PTE GND GND NO NC VAUX C Unit...

Page 41: ...L AL LB GND LB AL DOL VAUX C NO S3 Term ON Term OFF 3 1 ART 6388 5 4 3 8 7 6 ON 2 1 4 3 ON 2 1 Videophone Extension N BUS1 BUS2 GND 12VM GND DOL AL LB GND LB AL DOL VAUX C NO S3 Term ON Term OFF 4 1 ART 6388 Local Bell Local Bell Local Bell 5 4 3 8 7 6 ON 2 1 4 3 ON 2 1 Videophone Extension N BUS1 BUS2 GND 12VM GND DOL AL LB GND LB AL DOL VAUX C NO S3 Term ON Term OFF 1 1 ART 6388 5 4 3 8 7 6 ON 2...

Page 42: ...ND LB AL DOL VAUX C NO S3 Term ON Term OFF 7 1 ART 6388 5 4 3 8 7 6 ON 2 1 4 3 ON 2 1 Videophone Extension N BUS1 BUS2 GND 12VM GND DOL AL LB GND LB AL DOL VAUX C NO S3 Term ON Term OFF 8 1 ART 6388 Local Bell Local Bell Local Bell 5 4 3 8 7 6 ON 2 1 4 3 ON 2 1 Videophone Extension N BUS1 BUS2 GND 12VM GND DOL AL LB GND LB AL DOL VAUX C NO S3 Term ON Term OFF 5 1 ART 6388 5 4 3 8 7 6 ON 2 1 4 3 ON...

Page 43: ...unicipauxenmélange L utilisateurdoitdoncremettrel équipementenfinde vieauxcentresdecollecteappropriésoulerestitueraurevendeurlorsdel achatd unnouveautyped équipementéquiva lent danslerapportdeunàun Deplus l utilisateuralapossibilitédeconférergratuitementauxdistributeurs sansaucune obligation d achat de très petits DEEE pour les appareils ménagers sans dimensions extérieures supérieures à 25 cm La ...

Page 44: ...que demuestra su conformidad y puede ser distribuido en todos los estados miembros de la unión europea UE Este producto cumple con las Directivas Europeas 2014 30 EU EMC 2014 35 EU LVD 2011 65 EU RoHS marca CE 93 68 EEC Het product heeft de CE markering om de conformiteit ervan aan te tonen en is bestemd voor distributie binnen de lidstaten van de EU zonder beperkin gen Dit product volgt de bepali...

Reviews: