MOUNTING AND CONNECTING
-14-
Selection of correct payload (switch 09 and 10 / DIP I)
The P/T unit is designed for a max. payload of 15 kg. In order to guarantee an optimum
start drive for the used camera, you can select between “
≤
5 kg”, “> 5 kg” and “
≤
5 kg /
tracking mode” camera load.
Switch 9
Switch 10
Weight
Off
Off
≤
5 kg
On
Off
> 5 kg
Off
On
≤
5 kg /
tracking mode
The unit comes factory set with a payload of "
≤
5 kg". This corresponds to the
videotronic Vitect camera housing.
Control via RS-485 is not possible in tracking mode.
Software:
switch 11 / DIP I
Switch 11
Interface
On
RS-232
Off
RS-485
To activate the software for RS-232 or RS-485 control, please set switch 11 (DIP I) as
shown in the above table. Please make sure that among software settings, also the
hardware settings have to be changed accordingly.
Hardware:
switch 1 - 4 / DIP II
To change the hardware settings, use switches 1-4/DIP II as shown in the table below.
The factory setting is RS-485 active.
RS-485
RS-232
switch 1
Off
On
switch 2
On
Off
switch 3
Off
On
switch 4
On
Off