background image

EXHIBIT

-25-

Connecting the KB-485

The KB-485 keyboard can control all of videotronic infosystems’ RS485 devices. The
corresponding key commands for controlling the individual devices are described in this
chapter.

Key Assignment

Key

Function

0 - 9

numeric digit

monitor symbol

monitor selection

camera symbol

camera selection

REC

record

S/P

save position

H/T

home position time

G

group

P

position

T

time

SEQ

sequence

PAN

panorama

L/P

last position

R

reset

F1 / F2

function keys 1 and 2

F - keys

focus

Z - keys

zoom

Joystick

left, right, up, down

control pan/tilt head

turn joystick (left / right)

zoom (in / out)

Summary of Contents for SN-15AH PPHS

Page 1: ...1 Mounting and Operation Instructions for Variable High Speed P T Head 03 03 SN 15AH PPHS ALU Art No 560413...

Page 2: ...1...

Page 3: ...ts 15 Change from F BAS to Y C Operation 15 Activating Current Loop RTS CTS RS 232 15 Configuring the Tracking Mode 16 Commissioning Configuring the Vertical Axle 19 Correlation of Speed 19 Setting th...

Page 4: ...Before installing the device the end positions of the P T unit have to be adjusted to the local conditions at site 5 If any liquid or solid matter should get into the housing disconnect the unit from...

Page 5: ...s suitable for continuous operation Regular service and or maintenance are not necessary The integrated RS 232 serial interface allows the unit to be adapted to any existing or future telemetry system...

Page 6: ...trol with Video Matrix Control of the entire system is done over the RS 485 interface of the KB 485 keyboard using a standard twisted pair telephone cable shielded To allow selection of specific camer...

Page 7: ...ra unit to the bracket of the motor using the attached screws The camera can also be mounted upside down depending on the application 4 When connecting the system cable see correct polarity of the cab...

Page 8: ...MOUNTING AND CONNECTING 8 Connecting the Telemetry Receiver...

Page 9: ...low RS 485 B or RS 232 TxD green RS 485 A or RS 232 RxD Cable Type II Video Outputs and Current Loop black current loop or RS 232 CTS red current loop or RS 232 RTS white video signal F BAS or Y Y C b...

Page 10: ...ld of the coaxial cable has to be fixed with the strain relief clamp Set the FBAS Y jumpers as shown in the drawing Y C Operation With a separated transmission of brightness and colour information Y C...

Page 11: ...ared to additional coaxial connections Via twisted pair you can achieve transmission distances of up to 1 500 metres Inside the service junction box of the P T head you need an additional plug in circ...

Page 12: ...RS 232 CTS Clear to Send RTS Ready to Send TxD Transmit Data RxD Receive Data Please note that you can only use one control interface at a time When installing the device you have to determine either...

Page 13: ...er to have access to the DIP switch blocks on the control circuit board Setting the device address switch 1 8 DIP I The RS 485 device address of the camera station has to be set using the DIP switches...

Page 14: ...onds to the videotronic Vitect camera housing Control via RS 485 is not possible in tracking mode Software switch 11 DIP I Switch 11 Interface On RS 232 Off RS 485 To activate the software for RS 232...

Page 15: ...he video matrix must have the system address 00 since only this address can process the alarm message of the camera station For further information please ask for the corresponding operating instructi...

Page 16: ...his interface has to be set when the device is installed see under configuration of the camera station and configuration of the junction box As factory setting the RS 485 interface is pre set Configur...

Page 17: ...tering the software the switches 9 11 have to be set according to the table shown below Switch 9 Switch 10 Off On 5 kg tracking mode For activating the software for RS 232 control switch 11 DIP 1 has...

Page 18: ...s When the self test has been completed the unit is fully operational and can be controlled via the configured interface Configuration of vertical axle Depending on the position in which the compact c...

Page 19: ...ud screws of the corresponding axle adjustment of vertical limit switches 60 adjustment of horizontal limit switches 175 go to the desired limit switch position using the test sockets fix the stud scr...

Page 20: ...e corresponding 2 digit position number If this camera position shall be overwritten with a new position enter S P The previously called camera position will be stored with the new picture detail Stor...

Page 21: ...r P XX L P Panorama P 01 P xx 2 Start panorama function Enter PAN 3 Stop panorama function Enter Strike any key to stop the panorama function Programming the position hold time during panorama mode 1...

Page 22: ...s done via the KB 485 keyboard Following entries are possible 1 Store home position Enter S P the selected camera position will be stored as home position 2 Define home position time Enter H T xx xx i...

Page 23: ...Connect the power supply adapter to the connector box pos 1 of the keyboard please refer to the drawing Plug the keyboard s junction plug pos 1a into the connector box pos 1 The correct power supply i...

Page 24: ...0 0 0 0 1 1 03 0 0 0 0 0 1 0 0 04 0 0 0 0 0 1 0 1 05 0 0 0 0 0 1 1 0 06 0 0 0 0 0 1 1 1 07 0 0 0 0 1 0 0 0 08 1 1 1 1 1 1 1 0 254 1 1 1 1 1 1 1 1 255 If a jumper is plugged the information is 0 if a j...

Page 25: ...n this chapter Key Assignment Key Function 0 9 numeric digit monitor symbol monitor selection camera symbol camera selection REC record S P save position H T home position time G group P position T ti...

Page 26: ...played type of receiver When selecting SN 15AH PPHS ALU Camera station selected address The currently selected address of the target client gets displayed 00 99 last command The last command gets disp...

Page 27: ...stant to wear Service lubrication resistant to wear even if continuously operated due to self lubricating gears Limit switches horizontal internally adjustable Limit switches vertical internally adjus...

Page 28: ...peed ESC s stores idle time for home position Pos 00 time last position called with ESC P xxx multiplied with 2 5 position number 00 de activates home position ESC H xxx set time xxx decimal for home...

Page 29: ...aaaa 0 4000 ESC X P xxxx Queries present zoom position xxxx w o significance Echo ESC P aaaa with 0 0255 ESC X Q xxxx Queries present focus position xxxx w o significance Echo ESC Q aaaa with aaaa 0 1...

Page 30: ...utside the definition area would result in an endless turning of the motors The p t head is automatically stopped after expiry of the timeout and the ESC PERR command is transmitted There s a linear c...

Page 31: ...ct is already connected to the plug housing a Stick the contact over the coaxial cable wire using S and crimp the two together b Stick in the coaxial inner wire all the way through It will connect aut...

Page 32: ...4321 879 97 Lahnstra e 1 D 24539 Neum nster Germany Irrt mer sowie nderungen die dem technischen Fortschritt dienen vorbehalten Technical specifications are subject to change without prior notice Best...