EN.V1
Installation manual XV
15
APN
USER
PASS
The first three GPRS parameters are given by your SIM card provider.
GPRS parameters are provided by the cellular carrier. It is necessary to enter the correct information
for the carrier you use.
Remark: GPRS Parameters are Case Sensitive! (use the M/m key of the keypad to
change between upper /lower case letters).
Be careful: Use arrows to
change from one parameter
to the other. Press on the
[YES] key only when you
want to modify a parameter!
(The APN code is provided by your cellular provider. These
parameters will change with the SIM card used. Ask your
cellular provider for additional information).
5.4 Monitoring Parameters
To configure or modify the monitoring parameters, go to:
CONFIGU [YES] >> MONITORING CONFIGU [YES] >> PARA [YES]
In this menu you have:
Monitoring? Enable or Disable
Account Number: provided by your monitoring station
Server addresses: parameters provided by your monitoring station
Calling Profile:
Three options are available:
Strategy: ETH + GPRS (GPRS for Back-up), ETHERNET ONLY, GPRS ONLY
Sequence
Alternating test: with alternating test enable, the panel will transmit the periodic test
alternatively only via Ethernet, and only via GPRS. With this mode it’s possible to
know what type of transmission is working well.
5.5 Periodic test
To configure or modify the periodic test parameters, go to:
CONFIGU [YES] >> MONITORING CONFIGU [YES] >> PERIODIC TEST + [YES]
The different parameters are:
Test frequency: 24 hours by default
Test Hour
System armed: If enabled, the panel will transmit the periodic test only if the system is
armed.
Summary of Contents for XV
Page 1: ......