background image

EN.V1  

 

Installation manual XV 

 

14

 

 

5.2 Configure the Special Arming mode 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 
To configure or modify a special arming mode, with the direction arrow go to the menu: 
 
CONFIGURATION  (LEVEL  4)  +  [YES] 

  ALARM  MODES  PROGRAMMABLE  +  [YES] 

  FULLY 

ARMED, SP1 and SP2 (use direction arrows to select the arming mode you want to  [YES]). 
 
For  each  arming mode,  it is  possible  to  specify  how  each  of  the  4  areas  will  be  armed  and  how  the 
system will behave during an alarm. 
 
Areas:      1  2 3 4 Each time you press the corresponding number, the system will toggle the arming     
States:     A A A A   state for the respective area. 
 
Press the [YES] key after this configuration step. The system will then display what siren mode will be 
in effect for this special profile.  Select the siren mode using the direction arrows then press [YES]. 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

5.3 GPRS Parameters 

 

To configure or modify the GPRS parameters, go to: 

CONFIGURATION (LEVEL 4) + [YES] >> GENERAL PARA [YES] >> GPRS PARA [YES] 

In this menu you can modify advanced GPRS parameters: APN, User Name, Password, Packet Size, 
Data Time Out, SMTP GPRS, Port GPRS, Max TCP packet, Ringtone. 

 

Summary of Contents for XV

Page 1: ......

Page 2: ...adio range The XV can also have two wired speaker microphone units for full duplex audio verification Supervised Wireless Technology The XV GPRS along with all Videofied devices uses the patented S2View Interactive AES Encrypted Wireless technology providing optimum signal integrity and security The bi directional RF communication path between all devices and the system control panel guarantees hi...

Page 3: ... XV Programming 5 3 XV Panel 11 4 TP200 Speakers Microphone 12 5 Configuration 13 6 Level test GPRS error 17 7 Specials codes 17 8 Programmable Wired Inputs 18 9 Mapping Function 18 10 Programmable Wired Output 19 11 XV Power Values 20 12 XV Wireless Devices 20 15 XV Datasheet 21 ...

Page 4: ...DOES NOT HAVE TO BE PERFORMED IN ORDER TO PROGRAM THE PANEL How to Mount the Control Panel Fix the back casing on the wall with 3 screws to Open the Control Panel Use a screwdriver unscrew the 2 screws holding the panel together Install the SIM card Put the SIM card on the plastic base Take care to respect the right direction Slide it into the connector ...

Page 5: ... panel is now in Learn Mode for the CMA200 keypad Insert all three batteries into the CMA200 and press on both the ESC NO and CLR keys at the same time and release The indicator LED on the keypad will blink rapidly Other languages are available by scrolling with arrows ITALIANO NEDERLANDS DEUTSCH CASTELLANO SVENSKA PORTUGUES FRANCAIS Press YES for the selected one YES CLR ESC NO or for language se...

Page 6: ...airing with the control panel This test is the strength of communication between the device and the control panel The keypad will display a real time range out of 9 for the device that the test is running for To receive the most accurate results you must run the radio range test for at least 30 seconds The RF level test must be 8 9 or better for reliable transmission Wait while the screen changes ...

Page 7: ...ric Keypad to enter in a 4 8 digit account number provided by the Central Station YOU MUST ALWAYS CHOOSE YES Using the arrow keys YES to choose the Hour and Minute the periodic test will happen or for period selection and YES to apply YES YES YES YES YES TIME Minutes 15 00 TIME Minutes 15 15 11 10 01 15 15 ENTRY COMPLETE CONNECTED TO MONITOR STATION ACCOUNT NUMBER 99865123 PERIODIC TEST 24 HOURS D...

Page 8: ...ow to move to the next parameter You will use either a IP address or a Domain Name but not Both The Port is given to you by your Central Station By default the panel will use 888 If you need to modify the port press the YES key to enter into the parameter and the keypad to complete the port Press YES to confirm and the arrow to move to the next parameter Your Domain Name is given to you by your Ce...

Page 9: ... PARAMETERS APN CODE APN CODE xxxxx xxxxxx xxx USER NAME PASSWORD PASSWORD xxxxxxxxxxxx USER NAME xxxxxxxxxxx YES YES YES YES GPRS PARAMETERS ESC NO ESC NO Once you have entered all valid parameters press ESC NO to return to the main menu then ESC NO again to move to the next parameter GPRS LEVEL TEST IN PROGRESS YES END GPRS LEVEL x 5 YES YES During the GPRS Level test the Modem will boot and att...

Page 10: ... device you would like to program Before completing programming make sure that all tampers are depressed by verifying that each devices indicator LED is off Other values are available 2 min 1 min 45 sec Use the arrows for the selection and YES to confirm Others values are available 2 min 1 min 45 sec 30 sec 15 sec Use the arrows for the selection and YES to confirm Enter the name of the logical ar...

Page 11: ...d user The programming customization can give you many combinations of video voice inputs and outputs to match all of your customers needs XV Features Two Programmable inputs and one programmable output and have a mapping function that allows you to trigger a video from a Videofied Motion Viewer upon any event Two dedicated connectors to extend the GPRS and Radio range Two wired speaker microphone...

Page 12: ...re connected Maximum combined length 40 m if the first TP200 is 30 meters far from the panel the maximum length of the second cable for 2 nd TP200 will be maximum 10 meters On the panel s end strip the wire s cladding on at least 1cm for a proper contact to be established In case of acoustics problems The TP200 module has to be fixed to the wall to eliminate vibrations The TP200 module has to be f...

Page 13: ...From 999898 to 999999 All codes 1 From 314157 to 314159 All codes 2 A total of 186 codes are forbidden Access level Codes and badges get rights access to one of the 4 available levels of access Access level Definition rights LVL1 Stand by level LVL2 Restricted USER level where it is only possible to arm disarm the system LVL3 USER level where it is possible to arm disarm the system check the event...

Page 14: ...n alarm Areas 1 2 3 4 Each time you press the corresponding number the system will toggle the arming States A A A A state for the respective area Press the YES key after this configuration step The system will then display what siren mode will be in effect for this special profile Select the siren mode using the direction arrows then press YES 5 3 GPRS Parameters To configure or modify the GPRS pa...

Page 15: ...monitoring parameters go to CONFIGURATION YES MONITORING CONFIGURATION YES PARAMETERS YES In this menu you have Monitoring Enable or Disable Account Number provided by your monitoring station Server addresses parameters provided by your monitoring station Calling Profile Three options are available Strategy ETH GPRS GPRS for Back up ETHERNET ONLY GPRS ONLY Sequence Alternating test with alternatin...

Page 16: ...4 YES AREAS AND DEVICES YES SCHEDULING YES Scheduling Enable Enable all scheduled tasks Calendar Management In this menu you are able to create new scheduled tasks To create a new scheduled task press YES OK Use the or to set the Hour Use the or to set the minutes Use the or to set ARM close or DISARM Open Select the day press 1 for Monday 2 for Tuesday 7 for Sunday Several days can be select for ...

Page 17: ...IM card has to be deactivated or 00000 7 Specials codes Codes Action 999999 Maintenance request GPRS transmission 999997 Give the information that the panel detects main power or not 999991 The panel will send a test alarm to the first IP address configured in the menu Address Server In case of failure the panel will not stay blocked in transmission Very long time This code can be use just to test...

Page 18: ...ll transmit a panic event 9 Mapping Function The mapping function is available on the XV panel configuration With this option it is possible to ask for one DCV200 or DCV250 a ten video second on event or when a programmable input triggered Cf Appli note_Prog_Input Example of an application using the mapping a panic button is connected to the wired programmable input when the end user press the pan...

Page 19: ...ut One wired programmable output is available on the XV IP panel To use and configure this programmable output please read the application note Prog_Output Example of an application using the programmable output on intrusion trigger a spot light for 3 minutes ...

Page 20: ...1 Installation manual XV 20 11 XV Power Values Below is the table of values accepted by the XV panel 12 XV Wireless Devices Compatibility The XV GPRS works with all the following Videofied wireless devices ...

Page 21: ...ormation Programming Alphanumeric Keypads Devices per system 25 per system Access codes 20 maximum Arming modes 2 Number of areas 4 History Event Log 4 000 events stored in flash memory Communicator Communicator type GPRS Protocol Frontel IP stack TCP IP VIdeo transmission By Frontel protocol to central monitoring station GPRS antenna Integrated External GPRS antenna Yes via MMCX connector Video V...