Electrical data

Power requirements (option 1)

Power supply Type B 

  9-12VDC / 1,2A

                     Low voltage limit  

5,15V

Backup  

6V with 4 

x 1,5 V  D  Alkaline batteries 

/LR20

                     Low battery limit  

4,2V

                     Battery life (average) 

1 year

                     Average current consumption (over 1h) 

450µA

                     Max current 

1,2A

RF S

2

View

®  

Technology

Radio type 

Bidirectional RF

Operating frequency 

868/915/920 MHz

Transmission security 

AES algorithm encryption

Radio jam detection 

Yes

Supervision Yes
Antenna  

Integrated

External radio antenna 

Yes via MMCX connector

Tamper detection

Tamper 

Wall and cover tamper detection

Programmable wired input

Number

 3

«Dry» contact 

Yes

Input voltage 

12 VDC (15VDC max)

Programmable wired outputs

Number

 2

Max switching voltage 

60VDC /30VAC

Max switching current 4A
Max switching power 

120 VA

Box

Physical and Environmental Datas

Operating temperature 

-10°/+40°C

Maximum relative humidity 

75%, non-condensing

Material ABS—ULV0
Dimensions 

225 mm x 180 mm x 55mm (LxWxD)

Weight 

520gr (without batteries) / 1600gr (with batteries) 

Installation/Mounting

Control Panel/Base 
 

Two screws secures control panel cover to base; Three screws  

 

secure control panel base to the wall

GPRS Transmission

Communicator

Communicator type 

GPRS/Ethernet

Security Protocol 

Frontel

IP Stack 

TCP/IP

Video transmission 

  

 

By Frontel protocol to central monitoring station

GPRS antenna 

Integrated

External GPRS antenna 

Yes via MMCX connector 

Video

 

Video format 

MPEG

Video size 

Depending on camera type

Video length 

10 seconds

Miscellaneous

Programming 

With remote Keypad

Remote Devices per system 

25 maximum

Access Badges/codes 

20 maximum

Special arming mode 

4

Number of Areas 

4

History / Event log 

4,000 events stored on  flash memory

Approvals

EN50131-1

: 2007 - Grade 2 – Class II

EN50131-3

:2009 - Grade 2 

RTC 50131-3

:2009

EN50131-4

:2009 Grade 2 

RTC 50131-4

:2009

EN50131-5-3

:2005 - Grade 2

EN50131-6

:2008 Grade 2 –Type B  & 

RTC 50131-6

:2008

NF C 48-212

:2004

NF EN50130-4

:1995; A1:1998; A2:2003 

NF EN50130-5

: 1998 Class II 

 

 

 

       

Français

•   Retirez les piles avant toute opération de maintenance !

•   Attention ! Il y a un risque d'explosion si l'une des piles  

  utilisées est remplacée par une pile de type incorrect !

•   Respectez la polarité lors de la mise en place des piles !

•   Ne jetez pas les piles usagées ! Ramenez-les à votre   

  installateur ou à un point de collecte spécialisé.

English

•   Remove battery before any maintenance !

•   WARNING, there is a risk of explosion if a battery is  

  replaced by an incorrect type!

•   Observe polarity when setting up the batteries!

•   Do not throw used batteries! Bring them to your    

  installer or a collection point.

Deutsch

•   Batterien vor jeglichen Wartungsarbeiten entfernen!

•   Vorsicht, es besteht Explosionsgefahr, wenn eine  

 

  Batterie durch eine Batterie falschen Typs ersetzt wird!

•   Achten Sie beim Einsetzen der Batterien auf die Polung! 

•  Entsorgen Sie Batterien nicht im normalen  

 

  Haushaltsmüll! Bringen Sie Ihre verbrauchten Batterien  

  zu den öffentlichen Sammelstellen.

Notes de sécurité / (EN) Security notes / (DE) Hinweise zur Sicherheit

8. Technical specifications and 

security notes

Summary of Contents for XT-iP 210

Page 1: ...XT iP 210 620 730 GPRS Control Panel I N S T A L L M A N U A L www videofied com Doc Ref 230 XT iP Last modification date June 2014 Firmware version XLP 04 04 05 XXX and later ...

Page 2: ...ofied devices uses the S2View patented technology Which is an interactive wireless and AES encrypted technology ensuring signal integrity and optimal security The reliability of the signal is guaranteed thanks to the two way radio frequency transmissions with all the peripherals of the Videofied product line The integrated antennas allow the system to be totally wireless thus preventing from the s...

Page 3: ...parameters configuration 12 XTENDER mode configuration 14 4 XT iP features guide 16 4 1 Get to access level 4 16 4 2 How to Arm Disarm the system 16 4 3 Arming and Siren Mode Configuration 17 4 4 Manage badges and access codes 18 4 5 Delete the keypad or any other device 20 4 6 Read the event log 21 4 7 Programmable inputs and outputs 21 4 8 Golden rules 22 5 Ethernet parameters 23 6 Transmitted e...

Page 4: ... SIM Card Installation 1 1 RJ45 cable connection Connect the RJ45 cable to the Ethernet port When the panel attempts a transmission via Ethernet a red LED on the connector will flash This will allow the installer to check whether the panel is connected to a valid network DonottouchtheRJ45cablewhenthepanelispowered www videofied com I N S T A L L M A N U A L 4 1 XT iP Panel setup ...

Page 5: ...ketholes Fixthebackcasingonthewallusingthethreemountingholesillustratedabove Mountingthepanelisnotrequiredforprogramming 1 3 Panel mounting www videofied com I N S T A L L M A N U A L 5 1 XT iP Panel setup ...

Page 6: ... It will displays one of the following screens 1 5 Pairing the remote keypad RSI c 2013 videofied com XX or Press on both CLR and ESC NO keys at the same time and release The indicator LED on the keypad will blink rapidly Wait for the keypad to pair If the keypad doesn t pair up with the panel and shows XX it certainly means that it is still paired to another system and needs to be reset Take the ...

Page 7: ...m capable of latching a 9 12Vcc voltage used for its arming disarming When the XT iP panel is used in XTENDER mode the system will only be able to arm and disarm by latching 9 12Vcc to its arming inputs Arming Input 1 and or Arming Input 2 When the voltage switches to 0V the panel will disarm automatically On a programmed panel you can choose between standalone and XTENDER modes from the menu CONF...

Page 8: ...d the control panel The keypad will display a real time radio range value on a scale of 9 To receive the most accurate results you must run the radio range test for at least 30 seconds Result must be 8 out of 9 or better for reliable transmission Using the Alphanumeric Keypad enter the Installer Code of your choice The Installer Code will be used for all future maintenance and configuration This c...

Page 9: ...e name blank by pressing ESC NO it will be named ACCESS 1 by default Please wait ADJUSTING DATE AND TIME DATE YEAR 12 To set the year OK orYES DATE MONTH 13 01 To set the month OK orYES You may proceed in the same way for Day Hour and Minutes 13 10 14 10 47 ENTRY COMPLETE ACCOUNT NUMBER CONNECTED TO MONITOR STATION OK orYES Use the Alphanumeric Keypad to enter in a 4 8 digit account number provide...

Page 10: ...ICATION Keypad display Actions and comments The CODE STATE MODIF menu is to configure the transmitted events to the monitoring station use the arrow keys to toggle between events and OK or YES to modify ALARM event transmitted upon occurrence ALARM END event is transmitted on occurrence and on event restoral NOT TRANSMITTED event is not transmitted however it will appear on the keypad Please liais...

Page 11: ...s To switch between UPPER and lower case use the M m key from CMA keypad or hold a digit key 0 9 for XMA XMB ESC NO STRATEGY ETH 2G3G 2G3G PARAMETERS ESC NO OK orYES TEST IN PROGRESS END OK YES 2G3G LEVEL 5 5 2G3G LEVEL 2G3G LEVEL OK orYES Once the 2G3G test completed the keypad will display one of the following results A level between 0 5 and 5 5 A GPRS Error code please see Chapter 7 2G3G errors...

Page 12: ...th the arrows ETHERNET OFF NO STATUS the Ethernet module is switched off Please verify that the Ethernet cable is connected and try again CABLE OR NETWORK ABSENT the panel doesn t detect Ethernet Cable or Network By setting the DHCP as ENABLED a new IP address will be assigned dynamically to the panel every time it connects to the network Network parameters will not be asked If the router forces a...

Page 13: ...REA 1 NAME ESC NO OK orYES OK orYES OK orYES ARMING PROFILE STANDALONE ARMING PROFILE FROM THE HOST EXIT DELAY 45 sec For the selection OK orYES ENTRY DELAY 15 sec For the selection Pleasegotopage15ifyouchose STANDALONE OK orYES Pleasegotopage14ifyouchose FROMTHEHOST 3 XT iP Panel Programming For full compatibility with EN50131 press OK orYES Otherwise press ESC NO Press ESC NO to default the area...

Page 14: ...will wait to arm after voltage is latched on the arming input This feature can be used as an exit delay we suggest you to enter the same value as your master system exit delay Enter the value you would like for the Arming Confirmation and press OK or YES OK orYES ARMING MODE MODE SLOW MODE FAST OK orYES OK orYES OK orYES The transmission delay value sets the delay between the detection of an event...

Page 15: ...or disarmed until a user code or badge is entered the installer code cannot arm or disarm the system Press OK or YES to register one or more badges ESC NO if you re not using any badges If you wish to use an user code please skip this step and when initial programming is completed go to the BADGES ACCESS CODES menu please refer to chapter 4 4 for further details Badges and codes are limited to 19 ...

Page 16: ...ess enter your user code and press OK orYES Press enter your user code and press OK orYES With remote badge reader BR250 N A Present your badge on the badge reader N A N A With remote keyfob N A N A Press Press 4 1 Get to Access level 4 Tue 29 10 11 23 DISARMED LVL 1 ACCESS LEVEL 1 ACCESS LEVEL LEVEL 1 ACCESS LEVEL LEVEL 4 OK orYES OK orYES To unlock and get access to the installer level 4 you nee...

Page 17: ...irection arrows then press OK YES A Armed D Disarmed P Perimeter bydefault allopeningcontacts E External bydefault allopeningcontacts withexternalaccess You can set your devices as External Perimeter ou External Perimeter Please go to the menu CONFIGURATION LVL 4 AREAS AND DEVICES DEVICES DEVICES CONFIGURATION DEVICE TYPE Siren Immediate triggering of all sirens Delay Beeps Entry Exit delay beeps ...

Page 18: ...ible at this level User Level 3 can create Level 2 or Level 3 access codes or badges LVL 4 INSTALLER level where it is possible to modify the setup of the panel To access Level 4 the approval of a Level 3 oe Level 2 user is required Installer Level 4 can creat the first Level 3 access code only How to return to the LVL1 After 1 min of no use of the keypad and no tests running the display returns t...

Page 19: ...t Select badge code then OK orYES DELETING CODE ACCESS 5 CODE DELETED BADGE OR CODE CODE NAME CONFIRM THE CODE ACCESS 2 ENTRY COMPLETE BADGES ACCESS CODES ENTER A BADGE CODE Enter a 4 6 digit user code and OK orYES or present a badge in front of the reader until you hear the registration beep OK orYES OK orYES OK orYES OK orYES OK orYES OK orYES Reserved Codes 000000 From 9998 to 9999 From 99998 t...

Page 20: ...ONFIGURATION GENERAL PARAMETERS OK orYES to select the device and press OK orYES XX DELETE AREAS AND DEVICES DEVICES ADD A NEW DEVICE DEVICE CONFIGURATION A1 KEYPAD KEYPAD 1 OK orYES OK orYES OK orYES Devices list OK orYES OK orYES www videofied com I N S T A L L M A N U A L 20 4 XT iP features guide ...

Page 21: ...iP control panel also offer a mapping feature Mapping option allows the input to generate a video clip via a MotionViewer when a programmable input is triggered and or when an event occurs Forfurtherinformationabouttheprogrammableinputsandoutputs pleaseconsultthefollowingapplicationnotesavailableonoursupportwebsite 240 XV XT PROG INPUTS APP NOTE 240 XV XT PROG OUTPUTS APP NOTE Prog Out COM Prog Ou...

Page 22: ...evicesneedstotoprotectanaccessandnotazone 8 Do not fix the keypad at the beginning of the installation as it will need to be portable during programming Always clean the lens of the cameras after the installation Use a clean dry cloth taking care not to exert pressure on the lens 9 10 To switch between UPPER and lower case use the M m key from the CMA keypad or hold a digit key 0 to 9 for XMA XMB ...

Page 23: ...red the panel will be connected constantly to the local Network In case of an alarm the alarm will be sent in few seconds to the monitoring station When the main power is cut the Ethernet module will switch off after a delay DELAY BEFORE OFF 30 by default in order to save battery life In case of an alarm the panel will at first connect to the local Network It adds few seconds to the total process ...

Page 24: ...ATE MODIFICATION Use the arrows to access CONFIGURATION level4 CONFIGURATIONMONITOR STATION MONITORINGPARAMETERS EVENTTRANS MODIFICATION Then use the arrows to determine the event to modify Press OK orYES to edit These are the default transmitted events DEVICE intrusions ALERT Panic Buttons PANEL LOW BATT TAMPER DEVICE LOW BATT PERIODIC TEST DURESS CODE FIRE MEDICAL ASSIST ETHERNET CABLE AC POWER ...

Page 25: ...or codes are subject to change by SIM card operators However the GPRS level test errors results in the majority of cases have the following causes SIM Card activation Delay Some operators require an additional delay up to 48 hours to activate automatic data transmission Please check with your operator prior to installation APN CODE USERNAME and PASSWORD The GPRS 2G3G settings are supplied by the o...

Page 26: ...P Stack TCP IP Video transmission By Frontel protocol to central monitoring station GPRS antenna Integrated External GPRS antenna Yes via MMCX connector Video Video format MPEG Video size Depending on camera type Video length 10 seconds Miscellaneous Programming With remote Keypad Remote Devices per system 25 maximum Access Badges codes 20 maximum Special arming mode 4 Number of Areas 4 History Ev...

Reviews: