INSTALL SHEET

OMVC

 OUTDOOR MOTION VIEWER

Perimeter protection

Tilt Tamper

The OMVC MotionViewer can detect 
manipulation thanks to its built-in electronic 
accelerometer.

This device can detect shocks, movements, 
wall or cover tamper but also changes in its 
orientation.

When a movement of the OMVC is detected, 
the LED lights up for 3 seconds.

When it is armed for the first time, the OMVC registers its position in space.

 If its orientation is 

significantly changed on its transverse or longitudinal axis, a tamper alarm is sent to the panel. As for every 
Videofied device, the tamper is active 24/7.

If the detector is moved, 

the TAMPER notification will be displayed on the keypad the next time the 

system is armed

Press OK/YES to acknowledge that notification and confirm the detector new 

position

. If the 

TAMPER

 event is set as 

ALARM/END

, a tamper restoral event is sent to the panel.

Longitudinal axis rotation

Transverse axis rotation

Tilt tamper disabling (only for OMVC version 07.06.04.XX and later)

The OMVC Motionviewer must be deleted from the panel memory to disable tamper.

1.  Delete the OMVC from the device configuration menu.

2.  Press and hold the OMVC initialization button for 5 seconds. The red LED will turn on for 2 seconds to confirm the 

setting. 

3.  Pair the OMVC back with your panel.

The re-enabling tamper procedure is the same as described above. When the tamper is enabled however, the red LED 

turns on for 2 seconds, turns off for half a second and turns back on for 2 seconds.

Summary of Contents for MotionViewer OMVC 200

Page 1: ...d other system devices in the order of the following steps Programming RF Testing program detector and all other devices into the control panel and test RF communication from each intended device location to the control panel Mounting mount detector at the tested location Mounting Use proper tools and hardware Mount camera between 2 5 m to 3 5 m height The OMVC MotionViewer detection distance may ...

Page 2: ...continuously or you receive a 9 9 indicating good communication with the control panel 9 Press OK YES to end radio range test then press ESC NO 10 The keypad displays AREA ALLOCATION AREA 1 Press either arrow button repeatedly until desired area number appear then press OK YES By default all devices in Area 1 are automatically delayed 11 The display shows NAME LOCATION Enter appropriate device nam...

Page 3: ...tilt even slightly has a big impact on the detection distance and on the blind area under the MotionViewer We recommend to slightly tilt the OMVC to reduce its detection range and avoid false alarms To precisely determine the tilt angle use a smartphone app like Smart Protactor Android or Pitch Gauge iOs Blind angle Max detection distance Tilt Mounting height Max detection distance OMVC Tilt angle...

Page 4: ...n will be displayed on the keypad the next time the system is armed Press OK YES to acknowledge that notification and confirm the detector new position If the TAMPER event is set as ALARM END a tamper restoral event is sent to the panel Longitudinal axis rotation Transverse axis rotation Tilt tamper disabling only for OMVC version 07 06 04 XX and later The OMVC Motionviewer must be deleted from th...

Page 5: ...oist surfaces Speed and direction of the movement OMVC setup tilt height sensitivity Important It is essential to monitor the proper functioning of the infrared detection using the FUNCTIONAL TEST feature in the panel MAINTENANCE menu A red status LED lights up when the OMVC is detecting Use that test to determine the pattern of the detection field Status LED Blind angle Detection beams Individual...

Page 6: ... to prevent intrusions aim the detector towards an access point sensitivity adjustment will have no effect if the installation doesn t comply with the installation recommendations described in this document Adjust sensitivity for the OMVC MotionViewer To change the OMVC sensitivity you need to change the detector name DEVICE CONFIGURATION CHANGE NAME DEVICE OK orYES To select the OMVC OK orYES Ent...

Page 7: ...s However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures Reorient or relocate the receiving antenna Increase the separati...

Page 8: ...rogrammable Color or B W Night video Automatic black white infrared Infrared illumination Automatic with 4 IR LEDs Infrared illumination distance Up to 12m Video Video format MJPEG WMV MJPEG DIFF Frame rate 5 images per second Video duration Programmable 10 seconds by default Video resolution QVGA 320x240 Average video file size 220 kb Image Format JPEG Resolution VGA 640x480 Average image file si...

Page 9: ...ervice or the company that installed the product STANDARDS AND CERTIFICATIONS OMVC 200 868MHz Europe Compliant with the annex IV of the R TTE Directive 1999 5 EC Intertek LSS EN50131 2 2 Id 16LHK0199 01 OMVC 601 902 928MHz FHSS Argentina Certification number C 17501 Canada IC RSS 247 issue 1 Id 8816A MV50 Columbia Costa Rica SUTEL 00914 SUTEL DGC 2017 Mexico IFT Certification number RCPSISI17 0298...

Reviews: