4
INSTALL SHEET
OMVC
OUTDOOR MOTION VIEWER
Perimeter protection
Tilt Tamper
The OMVC MotionViewer can detect
manipulation thanks to its built-in electronic
accelerometer.
This device can detect shocks, movements,
wall or cover tamper but also changes in its
orientation.
When a movement of the OMVC is detected,
the LED lights up for 3 seconds.
When it is armed for the first time, the OMVC registers its position in space.
If its orientation is
significantly changed on its transverse or longitudinal axis, a tamper alarm is sent to the panel. As for every
Videofied device, the tamper is active 24/7.
If the detector is moved,
the TAMPER notification will be displayed on the keypad the next time the
system is armed
.
Press OK/YES to acknowledge that notification and confirm the detector new
position
. If the
TAMPER
event is set as
ALARM/END
, a tamper restoral event is sent to the panel.
Longitudinal axis rotation
Transverse axis rotation
Tilt tamper disabling (only for OMVC version 07.06.04.XX and later)
The OMVC Motionviewer must be deleted from the panel memory to disable tamper.
1. Delete the OMVC from the device configuration menu.
2. Press and hold the OMVC initialization button for 5 seconds. The red LED will turn on for 2 seconds to confirm the
setting.
3. Pair the OMVC back with your panel.
The re-enabling tamper procedure is the same as described above. When the tamper is enabled however, the red LED
turns on for 2 seconds, turns off for half a second and turns back on for 2 seconds.