8
7. Technical data
Phoenix Inverter Smart
12/1600
24/1600
48/1600
12/2000
24/2000
48/2000
12/3000
24/3000
48/3000
24/5000
48/5000
Parallel and 3-phase operation
No
INVERTER
Input voltage range (1)
9,3 – 17V 18,6 – 34V 37,2 – 68V
Output
Output voltage: 230VAC ±2% 50 Hz or 60Hz ± 0,1% (1)
Cont. output power at 25ºC (2)
1600 VA
2000 VA
3000 VA
5000 VA
Cont. output power at 25ºC
1300 W
1600 W
2400 W
4000 W
Cont. output power at 40ºC
1200 W
1450 W
2200 W
3700 W
Cont. output power at 65ºC
800 W
1000 W
1700 W
2800 W
Peak power
3000 W
4000 W
6000 W
10000 W
Dynamic (load dependent) DC
low shut down (fully
configurable)
Dynamic cut-off, see
https://www.victronenergy.com/live/ve.direct:phoenix-inverters-dynamic-cutoff
Max. efficiency 12/ 24 /48 V
92 / 94 / 94%
92 / 94 / 94%
93 / 94 / 95%
95 / 96%
Zero load power 12 / 24 / 48 V
8 / 9 / 11 W
8 / 9 / 11 W
12 / 13 / 15 W
18 / 20 W
Zero load power in ECO mode
0.6 / 1.3 / 2.1 W
0.6 / 1.3 / 2.1 W
1.5 / 1.9 / 2.8 W
2.2 / 3.2 W
GENERAL
Programmable relay (2)
Yes
Stop & start power ECO-mode
adjustable
Protection (3)
a - g
Bluetooth wireless
communication
For remote monitoring and system integration
VE.Direct communication port
For remote monitoring and system integration
Remote on-off
Yes
Common Characteristics
Operating temperature range: -40 to +65ºC (fan assisted cooling)
Humidity (non-condensing): max 95%
ENCLOSURE
Common Characteristics
Material & Colour: steel (blue RAL 5012; and black RAL 9017) Protection category: IP 21
Battery-connection
M8 bolts
M8 bolts
12 V/24 V: 2+2 M8 bolts
48 V: M8 bolts
24 V: 2+2 M8 bolts
48 V: M8 bolts
230 V AC-connection
Screw terminals
Weight
12kg
13kg
19kg
29kg / 28kg
Dimensions (hxwhd)
485 x 219 x 125mm
485 x 219 x 125mm
533 x 285 x 150mm (12 V)
485 x 285 x 150mm (24 V/48 V)
595 x 295 x 160mm (24 V)
555 x 295 x 160mm (48 V)
STANDARDS
Safety
EN-IEC 60335-1
Emission Immunity
EN 55014-1 / EN 55014-2 / EN-IEC 61000-6-1
EN-IEC 61000-6-2 / EN-IEC 61000-6-3
Automotive Directive
ECE R10-5
1) Non-linear load, crest factor 3:1
2) Programmable relay that can a.o.
be set for general alarm, DC under
voltage or genset start/stop function.
AC rating: 230 V / 3 A
DC rating: 3 A up to 30 VDC, 0.2A
up to 70 VDC
3) Protection key:
a) output short circuit
b) overload
c) battery voltage too high
d) battery voltage too low
e) temperature too high
f) 230 V AC on inverter output
g) input voltage ripple too high