18
5.4.3 Exemplary settings
Example 1 is the factory setting (since factory settings are entered by computer, all DIP
switches of a new product are set to ‘off’).
DS-1 3 position switch
off
DS-2 Charge voltage
off
DS-3 Charge voltage
off
DS-4 Frequency
off
DS-5 Search mode
off
DS-6 Store setting
→
←
DS-1
off
DS-2
on
DS-3
off
DS-4
off
DS-5
off
DS-6
→
←
DS-1
on
DS-2
on
DS-3
on
DS-4
on
DS-5
on
DS-6
→
←
Example 1: (factory setting)
1
No 3 position
switch connected
2, 3
GEL 14.4 V
4
Frequency: 50Hz
5
Search mode off
6 S
tore setting: off→ on→ off
Example 2
1
No 3 position
switch connected
2,3
AGM 14,7V
4
Frequency: 50Hz
5
Search mode off
6 S
tore setting: off→ on→ off
Example 3
1
3 position
switch connected
2, 3
Tubular plate 15V
4
Frequency: 60Hz
5
Search mode on
6 S
tore setting: off→ on→ off
Store the settings by changing switch ds-6 from off to on, and then back to off.
The LEDs ‘charger’ and ‘alarm’ will flash to indicate acceptance of the settings.
6. MAINTENANCE
The MultiPlus does not require specific maintenance. It will suffice to check all connections
once a year. Avoid moisture and oil/soot/vapours, and keep the device clean.
Summary of Contents for MultiPlus 12/800/35
Page 22: ......
Page 44: ......
Page 66: ......
Page 88: ......
Page 110: ......
Page 111: ...EN NL FR DE ES Appendix www victronenergy com Appendix A overview connections ...
Page 113: ...EN NL FR DE ES Appendix www victronenergy com Appendix B installation information ...
Page 117: ...EN NL FR DE ES Appendix www victronenergy com APPENDIX F dimensions ...
Page 118: ......
Page 119: ...www victronenergy com ...