• When used with the MultiPlus 500VA-1200VA models, connect the black wire to the ON terminal and the red wire to the
(+) terminal.
• When used with the MultiPlus 1600VA model, connect the black wire to the left terminal and the red wire to the right
terminal.
• When used with the MultiPlus Compact 800VA-2kVA models, connect the black wire to the middle terminal and the red
wire to the right (IN) terminal.
Both, the Load disconnect and Charge disconnect outputs of the BMS, must be in ‘High’ state in order for the MultiPlus to
operate. After shutdown due to low battery voltage, run the alternator or use a battery charger on the primary side of the
BMS to reset the system. The MultiPlus will then switch on and start charging (if connected to an AC power source).
•
MultiPlus-II and MultiPlus 3kVA or more:
For more info on how to configure the MultiPlus to work with the Smart BMS 12-200 please refer to the document on
our website:
• The Load disconnect and Charge disconnect outputs will be wired to the MultiPlus with two
(article number ASS030550100).
Smart BMS 12-200
Page 12
Appendix