EN
NL
FR
DE
SE
DA
battery was (nearly) fully charged and increases to 8 hours
in case of a deeply discharged battery.
3.
RECONDITION
Optional reconditioning for deeply discharged lead-acid
batteries.
Reconditioning is applicable to the charge algorithms
NORMAL and HIGH and can be selected with the App on
your smartphone.
When in RECONDITION mode the battery will be charged
with low current up to a higher voltage at the end of the
absorption phase.
During reconditioning the maximum current is equal to 8%
of the nominal current until the maximum voltage is
reached. Reconditioning is terminated after one hour or
when the maximum voltage is reached, whichever comes
first.
See table.
Example:
For a 12/7 charger: the recondition current is
7 x 0.08 = 0.56A
4.
FLOAT
Keeps the battery at constant voltage and fully charged.
5.
STORAGE
Keeps the battery at reduced constant voltage to limit
gassing and corrosion of the positive plates.
Slow self-discharge is prevented by an automatic weekly
refresh of the battery with a short absorption charge.
3.2 Lithium-ion (LiFePO
₄
) batteries
When charging a Lithium-ion battery, the
Blue Smart IP67
Charger
uses a specific charging algorithm for Lithium-ion
batteries, to ensure optimum performance.
Select LI-ION with
the app on your smart phone.
3.3 When a load is connected to the battery
A load can be applied to the battery while charging, as long as
the current draw is much lower than the rated output of the
battery charger.