• Duct system must terminate to the outside (roof or side wall).
• DO NOT terminate the duct system in an attic or other enclosed area.
•
DO NOT use 4” (10.2 cm) laundry-type wall caps.
• Use metal/aluminum duct only. Rigid metal/aluminum duct is recommended.
• DO NOT use plastic duct.
•
Always keep the duct clean to ensure proper airflow.
•
Calculate the following figures before installation:
1.
Distance from the floor to the ceiling.
2.
Distance from stove/countertop to range hood
3.
Height of hood and duct cover.
For the most efficient & quiet operation:
•
A distance of 26” to 30” is recommended* between stove top and the bottom of range hood
•
It is recommended that the range hood be vented vertically through the roof through 6” or bigger round metal/
aluminum duct work.
• The size of the duct should be uniform.
•
Use no more than three 90° elbows.
•
Make sure there is a minimum of 24” (61 cm) of straight duct between the elbows if more than one elbow is used.
• DO NOT install two elbows together.
•
The length of duct system and number of elbows should be kept to a minimum to provide efficient performance.
•
The duct system must have a damper. If the wall cap has a damper, DO NOT use damper (if supplied) on top of the
range hood.
•
Use aluminum foil tape to seal all joints in the duct system.
•
Use caulking to seal exterior wall or roof opening around the cap.
USE 6” ROOF OR WALL VENT CAP
MINIMUM.
IMPORTANT:
•
A minimum of a 6” round duct (standard for this range hood) must be used to maintain maximum airflow
efficiency. There is also an option to use an 8” round duct size for this unit.
•
Always use rigid type metal/aluminum ducts if available to maximize airflow when connecting to provided
duct.
• Please use Duct Run Calculation below to compute total available duct run when using elbows, transitions
and caps.
•
ALWAYS, when possible, reduce the number or transitions and turns in the duct run. If a long duct run is re-
quired, increase the duct size from 6” to 8”. If a reducer is used, install a long reducer instead of a pancake
reducer. Reducing the duct size will restrict airflow and decrease efficiency.
•
If turns or transitions are required: Install as far away from opening and as far apart, between 2, as pos-
sible.
•
Minimum mount height between stove top to hood bottom should be no less than 24-inch*.
•
Maximum mount height between stove top to hood bottom should be no higher than 32-inch*.
•
It is important to install the hood at the proper mounting height. Hoods mounted too low could result in heat
damage and fire hazard; while hoods mounted too high will be hard to reach and will loose its performance
and efficiency.
•
If available, also refer to stove top manufacturer’s height clearance requirements and recommended hood
mounting height above range.
Minimum Duct Size:
•
Round - 6” minimum
•
Round - 8” recommended/optional
* Due to different ceiling height configurations, recommended height may not be applicable.
VICTORY range hoods
| TWISTER
6
VICTORY range hoods
TWISTER | 7
VENTING REQUIREMENTS