background image

NOTICE:

For residential use only.

Installer:

Leave this guide with

the homeowner.

Homeowner:

Keep this guide for

future reference.

Professional Wall-Mount Range Hood

Model Name:

Available Sizes:

TWISTER

30”, 36”, 42”, 48”

Rev. 3062u.3a

INSTALLATION GUIDE

AND USERS MANUAL

Summary of Contents for Twister MAX

Page 1: ...nly Installer Leave this guide with the homeowner Homeowner Keep this guide for future reference Professional Wall Mount Range Hood Model Name Available Sizes TWISTER 30 36 42 48 Rev 3062u 3a INSTALLA...

Page 2: ...imensions 11 Preparation 13 Pre Installation 14 Installation 15 Venting Methods side view 19 Venting Methods front view 20 Back Exhaust Option 21 Wiring Diagram 22 Range Hood Operations 22 Troubleshoo...

Page 3: ...wer from being switched ON accidentally Clean grease laden surfaces frequently To reduce the risk of fire and to disperse air properly make sure to duct air outside DO NOT duct exhaust into spaces bet...

Page 4: ...ws to disperse the gas If you still smell gas call the gas company and fire department or dial your local emergency service immediately Your safety and the safety of others is very important We have p...

Page 5: ...ctrical inspector s use The range hood must be connected with copper wire plug only The range hood should be connected directly to the fused disconnect or circuit breaker box through flexible armored...

Page 6: ...MUM IMPORTANT A minimum of a 6 round duct standard for this range hood must be used to maintain maximum airflow efficiency There is also an option to use an 8 round duct size for this unit Always use...

Page 7: ...aight duct run Subtract 30ft from the al lowable 50ft The remaining distance of 20ft is the longest that the straight ducting in addition to the duct pieces can be Body Stainless Steel 19 gauge Power...

Page 8: ...Putty Knife Marker or Pencil Tape Measure Level Phillips Screwdriver Aluminum Tape Power Drill Utility Knife Drywall Knife VICTORY range hoods TWISTER 8 REQUIRED TOOLS...

Page 9: ...x14 M4 4mm Bullet Head x8 NOTE Where necessary additional screws will be needed for installation and added support but is not included Please review contents before installation Screws included to ass...

Page 10: ...wer Chimney Upper Chimney Mounting Bracket 8 Transition Requested option 6 Transition Baffle Filters x2 Filter Handles x4 Range Hood Grease Tunnel VICTORY range hoods TWISTER 10 PARTS SUPPLIED Continu...

Page 11: ...OTTOM VIEW SIDE VIEW 3 10 1 4 FRONT VIEW 15 3 4 12 12 1 4 TOP VIEW 22 Available Sizes 29 3 4 35 3 4 41 3 4 47 3 4 6 12 1 Mounting Bracket Optional Vent Size 8 VICTORY range hoods TWISTER 11 DIMENSIONS...

Page 12: ...8 2 Optional Vent Size 3 22 12 From 17 to 30 10 Available Sizes 29 35 41 47 12 6 Vent Size 3 Model TWISTER VICTORY range hoods TWISTER 12 DIMENSIONS Continued...

Page 13: ...ng 1 Determine and mark the center line on the ceiling where the range hood will be installed Make sure there is proper clearance within the ceiling or wall for exhaust duct 2 Due to the weight and si...

Page 14: ...t configurations recommended height may not be applicable 1 Identify where your vent duct and power supply cable in relation to your range hood And if you have cabinets flanking the area of the hood r...

Page 15: ...idden from view Min Height 76 from the floor 3 Use knife and saw to cut out drywall to accommodate a plywood brace support The inserted plywood should be the same depth as the drywall slab it is repla...

Page 16: ...many mounting holes as needed to secure from the inside of hood 2 Apply spackle in between spaces of the plywood and drywall seamlessly Sand down any rough spackle to smooth out Paint area if required...

Page 17: ...nsition circumference edge 1 Centerline C e i l i n g Wall Fasten screws to hold chimney to mounting bracket Expand the upper chimney to sit flush against the ceiling Fasten screws to mount chimney on...

Page 18: ...Baffle Filter Angle filter toward front of hood opening above the front light and control panel Slide toward and into the recess behind the front of hood while raising the filter at the rear Lower fil...

Page 19: ...ct work can terminate either through the roof or wall To vent through a wall a 90 elbow is needed IMPORTANT NEVER exhaust air or terminate duct work into spaces between walls crawl spaces ceiling atti...

Page 20: ...Duct required for all remote blower installations Optional Remote Blower Min 26 Max 30 30 min for 9 ceiling Power Outlet Min 76 from floor 96 Max 108 Due to different ceiling height configurations rec...

Page 21: ...ood comes with a back exhaust option additional charges will apply to make the hood rear vented This option must be purchased prior shipping Changing from the top vent to back vent onsite can be diffi...

Page 22: ...ontrols the lights BLOWER SWITCH Rotate the switches clockwise to switch the blower ON The switch has 5 positions OFF SPEED 1 2 3 4 LIGHT SWITCH Rotate the switches clockwise to switch the lights ON T...

Page 23: ...create extra noise and vibrations Check if duct is clogged or if damper unit is not installed correctly or opening properly A tight mesh on a side wall cap unit might also cause restriction to the air...

Page 24: ...ER cook on open flames under the range hood Check deep fryers during use Superheated oil may be flammable Cleaning The saturation of greasy residue in the blower and filters may cause increased inflam...

Page 25: ...eel polish such as 3M or ZEP to polish and buff out the stainless luster and grain Always scrub lightly a with clean cotton cloth and with the grain DO NOT allow deposits to accumulate or remain on th...

Page 26: ...a business card or plastic palette knife to preduct scratches on the metal finish and insert in between the switch panel and LED bulb housing Work your way around 2 until the light housing pops out 3...

Page 27: ...ange Hood Outer Ring GU10 LED Bulb Inner Ring To re assemble simply reverse the steps 6 to 2 To re install 7 press the bulb housing carefully and firmly into the recess until you hear a positive snap...

Page 28: ...per maintenance use of corrosive and abrasive cleaning products pads and oven cleaner products Chips dents or cracks due to abuse misuse freight damage or improper installation Damage of product cause...

Page 29: ...good working condition with ALL original parts and documentation packed in all original cartons fillers and shipping cartons A restocking fee of 10 will be charged for all approved return s Exchanges...

Page 30: ...583 Nicola Avenue Port Coquitlam BC Canada V3B 0M3 www kitchenhoods ca...