Setting the altimeter 

 
 
 
 
 
 
 
Press  the  Victorinox  emblem  for 

4

  seconds  until 

the  display  flashes.  Now  release  the  Victorinox 
emblem  again.  You  have  changed  over  to  the 
altimeter setting mode. 
 
 
 
 
 
 
 
 
The  arrow  shows  the  present  adjustment  direc-
tion. The changeover is automatic. 
 
 
 
 
 
If  the  Victorinox  emblem  is  pressed  for  a  longer 
period  (at  least 

6

  seconds),  the  adjusting  speed 

is increased (20 digits/s). 
 
 
 
 
 
Brief pressure on the Victorinox emblem changes 
the  display  by  1  digit  (meter).  To  increase  the 
value  which  is  shown,  press  the  Victorinox 
emblem  repeatedly  while  the  arrow  points  up-
wards. When the correct altitude is shown on the 
display, wait for 

10

 seconds until the system has 

accepted the entry made by you. 
 
 
 
 
 
 
 
The  display  then  changes  over  to  the  "Weather 
correction mode". When the Victorinox emblem is 
pressed  briefly,  the  correction  setting  can  be 
altered in the sequence "Stnd", "Cold", "Hot". 

 

Stnd

  standard  temperature  for  a  particular 

altitude (tolerance ±5°C) 

Cold

  colder  than  standard  (difference  greater 

than 5°C) 

Hot

 

warmer  than  standard  (difference greater 
than 5°C) 

(Standard values see table on page 4) 

 
 
 
 
 
If the button is not pressed within 

4

 seconds, the 

"Weather  correction  mode"  is  quit  automatically 
and the new setting accepted. 
 
 

Warning!!! 

To  extend  the  battery  life  many  times  over, 
the  altitude  display  has  a  built-in  delay, 
therefore,  the  altimeter  must  not  be  used 
during sky diving or other similar sports. 

 
 
 

Altitude  error  /  Impact  of  atmospheric  pres-
sure fluctuations 

A  change  in  the  weather  causes  the  barometric 
pressure  to  alter;  this  in  turn  means  that  the 
displayed  altitude  differs  from  the  effective 
altitude. The error can be eliminated by adjusting 
the  altitude.  Even  on  a  stable  day,  temperature-
related air pressure fluctuations of ±1 mbar may 
occur;  this  is  equivalent  to  an  altitude  error  of   
±8  meters.  Under  normal  weather  variations,  an 
altitude difference of 40 – 50 m may easily occur 
after  a  single  day.  If  the  pressure  difference  is 
great  (storm  front),  a  change  of  up  to  100  m  is 
also realistic. Over a two-day period, a difference 
of  200  –  250  m  may  occur  in  the  event  of  ex-
treme weather changes. 
 
1 mbar > approx. 8 m 
(or approx. 16 m at 5'500 m above sea level) 
1 hPa = 1 mbar = 0.001 bar = 0.75 mmHg 
 
Because  of  these  air  pressure  fluctuations,  an 
altimeter must always be readjusted before use. 
Set the altitude on a daily basis if you are hiking 
or  climbing  or  wish  to  take  account  of  weather 
changes. This  means that  the  altimeter  must  be 
reset  at  a  known  altitude  (e.g.  at  home,  at  a 
railway station, mountain hut etc.). 

Summary of Contents for Expedition Lite

Page 1: ...mode 24h is already preset Initial startup ft F 12h To set the American system of units height ft temperature F time mode 12h Insert new battery press the Victorinox emblem while closing the battery c...

Page 2: ...re on the Victorinox emblem alters the display by one digit in the arrowed direction If the button is not pressed within 10 seconds the setting mode is quit automatically and the new display accepted...

Page 3: ...ds the Weather correction mode is quit automatically and the new setting accepted Warning To extend the battery life many times over the altitude display has a built in delay therefore the altimeter m...

Page 4: ...0 26 24 719 10 3000 9 843 4 50 23 90 701 09 3400 11 155 7 10 19 22 666 15 3800 12 467 9 70 14 54 632 64 4000 13 123 11 00 12 20 616 40 4500 14 764 14 25 6 35 577 28 5000 16 404 17 50 0 50 540 20 5500...

Page 5: ...uiva lent to 3 hPa 3 mbar If the difference over a 4 hour period is greater than 7hPa the segments which extend beyond the range of 6hPa begin to flash This is a clear indication that the air pressure...

Page 6: ...e on the Victorinox emblem causes the display to change by one digit in the arrowed direction If the button is not pressed within 10 seconds the setting mode is quit automatically and the new display...

Page 7: ...nox emblem briefly Restart Countdown The countdown can be started with the value set previously Press the Victorinox emblem for 2 seconds until a beep tone is heard and the display flashes The countdo...

Page 8: ...he background lighting can be switched on again if the battery voltage rises In normal operation the battery voltage is meas ured at 15 minutes intervals or whenever the menu is changed If the voltage...

Reviews: