TOOL SETUP
WARNING
• Do not connect power until instructed
otherwise.
• Tool must be lifted with a hoist and plate
clamp to safely handle the tool weight
(302 pounds/137 kg).
Failure to follow these instructions may
result in serious personal injury.
1.
Remove all components and check to ensure
that all necessary items are included . Refer to
the “Receiving the Tool” section .
2.
Select a location for the tool and pipe stand .
Choose a location that has:
a.
The required power . Refer to the “Power
Requirements” section
b.
The space necessary to adequately
handle the pipe to be grooved
c.
A level surface for the tool and pipe
stand
3.
Place the tool on a level surface . Place a level
on top of the plate and cylinder to verify that the
tool is level front to back and side to side .
4.
Verify that the hydraulic system is full of oil .
Refer to the “Maintenance” section for hydraulic
oil requirements .
TOOL DIMENSIONS
43.3 inches
1100 mm
51.2 inches
1300 mm
32.3 inches
820 mm
TOOL SPECIFICATIONS
Tool weight: 302 pounds/137 kg
Voltage: 120-volt, single phase
Frequency: 60 Hz 15A
Capacity of oil reservoir: 5 fl oz/150 ml
9
REV_C
TM-RG3212
/ Operating and Maintenance Instructions Manual